Furuno SC-60 Replacement of Fuse, Error Messages, Message display, Error Message Meaning Remedy

Models: SC-60

1 106
Download 106 pages 24.46 Kb
Page 65
Image 65

4. MAINTENANCE, TROUBLESHOOTING

4.7Replacement of Fuse

The 3 A fuse on the POWER Board inside the processor unit protects the equipment from overcurrent and reverse polarity of the power supply. If the fuse blows, have a qualified technician check the set and replace the fuse.

CAUTION

Use the proper fuse.

Use of a wrong fuse can cause fire or damage to the equipment.

4.8Error Messages

The alarm sounds for equipment error and is accompanied by a flashing exclamation mark (). Press any key to silence the alarm. The exclamation mark remains on the screen until the cause for error is eliminated. Find the cause for the alarm(s) as follows:

1.Press the [MENU] key to open the menu.

2.Choose MESSAGES and press the [ENT] key.

MESSAGES

GPS DATA ERROR!

Message display

3.Press the [DISP] key to close the menu. Error messages

Error Message

Meaning

Remedy

ABORTING!

GPS heading error continues for

Check for obstruction.

 

one minute. For example, satellite

 

 

cannot be acquired because of

 

 

unfavorable environment.

 

ABORTING CALC!

GPS signal interrupted for one

Press any key to try to restore

 

minute

normal operation.

BACKUP ERROR!(DISP)

Corrupted backup data found in

Default settings are

 

display unit at power on.

automatically restored.

BACKUP

Corrupted backup data found at

Default settings are

ERROR!(PRCSSR)

processor unit at power on.

automatically restored.

(Continued on next page)

4-7

Page 65
Image 65
Furuno SC-60 manual Replacement of Fuse, Error Messages, Message display, Error Message Meaning Remedy, On next