Furuno SC-60 manual Heading data format, Jumper wire and format on the circuit board 20P8171

Models: SC-60

1 106
Download 106 pages 24.46 Kb
Page 35
Image 35

2. INSTALLATION

2.6.3Heading data format

1.Turn off the processor unit.

2.Unfasten four screws from the processor unit to remove the top cover.

3.Choose the heading format of the equipment connected to the ports HDG OUT 1, HDG OUT 2 and HDG OUT 3 with the jumper wires on the circuit board 20P8171, referring to the table below. The default setting for each port is AD-10.

Jumper wire and format on the circuit board 20P8171

Port

Format

Setting

 

Remarks

HDG OUT 1

AD-10

J11 < - > J13

NMEA and AD-10 are identified

 

 

 

 

on the circuit board. Choose

 

NMEA

J11 < - > J12

 

 

 

 

 

NMEA for IEC 61162-1

HDG OUT 2

AD-10

J14 < - > J16

 

 

sentences.

 

NMEA

J14 < - > J15

 

 

 

 

HDG OUT 3

AD-10

J17 < - > J19

 

 

 

NMEA

J 17 < - > J18

 

 

 

 

 

NMEA

 

 

 

(IEC 61162)

ANGULAR

HEAD1

 

AD-10

RATE SENSOR

 

 

 

BEACON

20P8171

NMEA (IEC 61162)

 

HEAD2

 

AD-10

HEAD3

AD-10

NMEA (IEC 61162)

Processor unit, cover opened, top view

2-21

Page 35
Image 35
Furuno SC-60 manual Heading data format, Jumper wire and format on the circuit board 20P8171, Port Format Setting Remarks