MT-76D2TAMPING RAMMER — MAINTENANCE

Cleaning the Air Cleaner

Clean the Air Cleaner every 200-300 hours. See Figure 11.

Remove element from pre-cleaner at the top of crankcase (body side).

Wash the element (outside) in detergent solution.

Shake out excess moisture and dry the element.

Clean inside element with air from the inside of element.

Figure 11. Air Cleaner

Cleaning the Oil Filter

Drain oil filter every 100 hours of operation. Replace the oil filter every 1,000 hours of operation. See Figure 12.

Figure 12. Oil Filter

Fuel Pipe & Oil Pipe

Check fuel line regularly for damage, paying attention to clamps to assure a tight fit.

Replace fuel line every two years to maintain original performance.

Transportation

Maintain upright position of rammer at all times.Transport rammer in upright position. If machine must be laid down for transportation, drain the diesel fuel first and lay machine with muffler side down. See Figure 13.

Figure 13. Transporting Rammer

The fuel filter is installed at the bottom of fuel tank. Should the rammer be laid on its side, dirt from the fuel filter may contaminate the injection nozzle, causing damage to the fuel pump.

Storage

When storing the rammer for long periods of time, thoroughly drain all fuel from line.

Clean exterior of rammer with an oil moistened cloth. Cover and store in a clean, dry place.

MT-76D2 TAMPING RAMMER —OPERATION AND PARTS MANUAL — REV. #5(11/08/07) — PAGE 19