MVH-200GHSTART-UP/SHUT-DOWN PROCEDURES

7.If the engine has started, slowly return the choke lever (Figure 13 ) to the CLOSED position. If the engine has not started repeat steps 1 through 6.

Figure 13. Choke Lever (Closed)

8.Beforethecompactoris placedintooperation,runtheengine for several minutes. Check for fuel leaks, and noises that would be associated with a loose component.

Shut-Down Procedure:

1.Return the throttle lever to the START position. Allow the machine to cool down for 2 to 3 minutes.

2.Turn the throttle lever to the STOP position (Figure 16) to stop the engine. In a motor start, return the key switch to the STOP position (Figure 14) as soon as the engine stops.

Figure 14. Throttle Lever (Stop)

3.Turn the engine ON/OFF switch to the OFF position (Figure 15).

Figure 15. Engine ON/OFF Switch (OFF)

4. Place thefuelshut-off lever (Figure 16) in the OFFposition.

Figure 16. Fuel Valve Lever (OFF) Emergency Shutdown Proucedure:

1.Move the throttle lever quickly to the STOP position (Figure 14).

2.Place the engine ON/OFF switch in the OFF position (Figure 15).

PAGE 18 — MVH-200GH PLATE COMPACTOR — OPERATION & PARTS MANUAL — REV. #2 (09/22/06)