MVH-200GH — START-UP/SHUT-DOWN PROCEDURES
7.If the engine has started, slowly return the choke lever (Figure 13 ) to the CLOSED position. If the engine has not started repeat steps 1 through 6.
Figure 13. Choke Lever (Closed)
8.Beforethecompactoris placedintooperation,runtheengine for several minutes. Check for fuel leaks, and noises that would be associated with a loose component.
Shut-Down Procedure:
1.Return the throttle lever to the START position. Allow the machine to cool down for 2 to 3 minutes.
2.Turn the throttle lever to the STOP position (Figure 16) to stop the engine. In a motor start, return the key switch to the STOP position (Figure 14) as soon as the engine stops.
Figure 14. Throttle Lever (Stop)
3.Turn the engine ON/OFF switch to the OFF position (Figure 15).
Figure 15. Engine ON/OFF Switch (OFF)
4. Place
Figure 16. Fuel Valve Lever (OFF) Emergency Shutdown Proucedure:
1.Move the throttle lever quickly to the STOP position (Figure 14).
2.Place the engine ON/OFF switch in the OFF position (Figure 15).
PAGE 18 —