Before Starting

1.Read safety instructions at the beginning of manual.

2.Place pump as near to water as possible,onafirmflat,levelsurface.

3.Toprimepump,removefillcap(Figure2)andfillpumpcasing with water.If the pump casing is not filled with water before starting, it will not begin pumping.

CAUTION

Pump casing must be filled with water before using pump. Otherwise pump will not be able to begin pumping.

WARNING

DO NOT open fill cap if pump is hot! Water inside may be under pressure.

4.Checkforleaksbetweenpumpandengine.Ifwaterisleaking between the pump and engine housing, the seal inside the pumpmaybewornordamaged.Continued operationofthe pumpisnot recommended.Furtherusageofthe pumpunder theseconditionsmaycauseseverewaterdamagetoengine.

Hoses and Clamps

1.Check that all hoses are securely attached to the pump. Make certain suction hose (Figure 2) does not have any air leakage.Tighten hose clamps and couplings as required.

2.Itisrecommendedthat 2 clampsbeusedwhensecuringthe suction hose to the inlet side (suction) of the pump.

3.Remember suction hoses must be rigid enough not to collapse when the pump is in operation.

4.Check that the discharge hose (Figure 2) is not restricted. Place hose so that it lays as straight as it is possible on the ground. Remove any twists or sharp bends from hose which may block the flow of water.

QP- 2TE — PRE-SETUP (PUMP)

Suction and discharge hoses are

NOTE available from Multiquip. Contact your nearest dealer for more information.

5.The discharge hose is usually a collapsible (thin-walled) hose, however if a thin-walled discharge hose is not avail- able, a rigid suction hose can be substituted in its place.

6.Make sure the suction strainer (Figure 2) is clean and securely attached to the water end of the suction hose. The strainer is designed to protect the pump by preventing large objects from being pulled into the pump.

CAUTION

The strainer should be positioned so it will remain completely under water. Running the pump with the strainer above water for long periods can damage the pump.

CAUTION

DO NOT pump flammable fluids, corrosive chemicals or fluids containing toxic substances. These fluids can create potentially dangerous health and environmental hazards. Contact local authorities for assistance.

CAUTION

This pump uses a water-cooled mechanical seal to prevent water from seeping into the engine. The passage of water through the pump casing lubricates the seal and prevents it from overheating. NEVER! operate the pump without water in the casing as this will cause damage to the mechanical seal.

QP- 2TE TRASH PUMP — OPERATION AND PARTS MANUAL — REV. #1 (08/10/10) — PAGE 19

Page 19
Image 19
Multiquip Qp-2TE QP- 2TE PRE-SETUP Pump, Read safety instructions at the beginning of manual

Qp-2TE specifications

The Multiquip QP-2TE is a highly regarded option in the realm of portable generators, designed to meet the demands of both commercial and residential applications. Renowned for its reliability and performance, the QP-2TE delivers exceptional power in a compact and user-friendly package.

At the heart of the Multiquip QP-2TE is a durable, high-performance engine that provides 2,000 watts of surge power and 1,600 watts of continuous power. This robust power output is more than sufficient for running essential equipment such as power tools, lighting, and even small appliances. The generator comes equipped with an easy-to-read fuel gauge, allowing users to monitor fuel levels at a glance, ensuring they can operate without interruptions.

The QP-2TE features a versatile power panel with multiple outlets. It includes both 120V and 12V DC outlets, enabling users to connect various devices simultaneously. The inclusion of a 120V, 20A duplex outlet adds to the generator's versatility, allowing it to power multiple tools at once or provide temporary power to an entire campsite. The generator's lightweight construction, weighing only around 45 pounds, ensures portability, making it suitable for outdoor events, job sites, or emergency backup power.

Technologically speaking, the QP-2TE integrates advanced features such as low oil shutdown and circuit protection. These safety mechanisms are crucial as they prevent damage to the engine and connected devices during operation, ensuring longevity and reliability. Its efficient cooling system also aids in preventing overheating, allowing the generator to function optimally for extended periods.

Another standout characteristic of the Multiquip QP-2TE is its whisper-quiet operation. Designed with noise reduction features, it operates at a remarkably low decibel level, making it ideal for use in residential neighborhoods or campgrounds where noise restrictions might be in place. Its fuel-efficient operation enhances its appeal, allowing users to maximize run time on a single tank of gas.

In summary, the Multiquip QP-2TE is a powerful, portable generator that combines rugged durability with advanced safety features and quiet operation. Its versatility, lightweight design, and efficient power output make it an excellent choice for those seeking reliable energy solutions in various settings. Whether for emergency power, outdoor activities, or job site operations, the QP-2TE stands out as a premium option in the portable generator market.