NEVER Run engine without air cleaner. Severe engine damage may occur.

ALWAYS read, understand, and follow procedures in Operator’s Manual before attempting to operate equipment.

ALWAYS be sure the operator is familiar with proper safety precautions and operation techniques before using pump.

ALWAYS store equipment properly when it is not being used. Equipment should be stored in a clean, dry location out of the reach of children.

NEVER leave the pump unattended, turn off engine when unattended.

Unauthorized equipment modifications will void all warranties.

NEVER pump volatile, explosive, flammable or low flash point fluids.These fluids could ignite or explode.

NEVER operate the pump in an explosive atmosphere.

Before starting the pump, check that the clean-out cover is securely fasten.

ALWAYS ensure pump is on level ground before use.

Become familiar with the components of the pump before operating.

ALWAYS replace any worn or damaged warning decals.

NEVER pump corrosive chemicals or water containing toxic substances. These fluids could create serious health and environmental hazards. Contact local authorities for assistance.

NEVER open the priming plug when pump is hot. Hot water inside could be pressurized much like the radiator of an automobile. Allow pump to cool to the touch before loosening plug.

NEVER open the pump housing during operation or start the pump with the clean-out cover removed.The rotating impeller inside the pump can cut or sever objects caught in it.

NEVER block or restrict flow from discharge hose. Remove kinks from discharge line before starting pump. Operation with a blocked discharge line can cause water inside pump to overheat.

ALWAYS fill the pump casing with water before starting the engine. Failure to maintain water inside the pump housing will cause severe damage to the pump.

In winter drain water from pump housing to prevent freezing.

RULES FOR SAFE OPERATION

High Temperatures – Always stop engine and allow the engine to cool before adding fuel, oil or performing service and maintenance functions. Contact with hot components can cause serious burns.

NEVER disconnect any "emergency or safety devices". These devices are intended for operator safety. Disconnection of these devices can cause severe injury, bodily harm or even death! Disconnection of any of these devices will void all warranties.

Maintenance Safety

NEVER lubricate components or attempt service on a running machine.

ALWAYS allow the machine a proper amount of time to cool before servicing.

Keep the machinery in proper running condition.

Fix damage to the machine immediately and always replace broken parts, or missing decals.

Dispose of hazardous waste properly.Examples of potentially hazardous waste are used motor oil, fuel and fuel filters.

DO NOT use food or plastic containers to dispose of hazardous waste.

DO NOT pour waste, oil or fuel directly onto the ground, down a drain or into any water source.

Emergencies

ALWAYS know the location of the nearest fire extinguisher.

ALWAYS know the location of the nearest first aid kit.

In emergencies always know the location of the nearest phone or keep a phone on the job site. Also know the phone numbers of the nearest ambulance, doctor and fire department. This information will be invaluable in the case of an emergency.

QP-301TH TRASH PUMP — PARTS MANUAL— REV. 4 (10/05/05 ) — PAGE 9

Page 9
Image 9
Multiquip QP-301TH manual Rules for Safe Operation

QP-301TH specifications

The Multiquip QP-301TH is a state-of-the-art portable generator designed to meet the diverse power needs of contractors, professionals, and outdoor enthusiasts. Known for its durability, performance, and reliability, this model is a popular choice in the generator market, especially among those requiring consistent and efficient power supply.

One of the main features of the QP-301TH is its robust engine. It is powered by a reliable Honda GX390 engine known for its fuel efficiency and low emissions. This engine offers a starting wattage of 3000 watts and a running wattage of 2400 watts, which is ideal for powering tools, small appliances, and equipment. The generator’s design allows for 120-volt output, providing versatility for various applications.

The QP-301TH also boasts a user-friendly control panel that simplifies the operation. It includes clearly labeled outlets, such as two 120V GFCI outlets and one 120V twist-lock outlet, ensuring easy connectivity to electrical devices. The generator is equipped with an electric start system, facilitating effortless ignition, which is particularly helpful in emergency situations or when the generator is needed quickly.

Portability and convenience are key characteristics of the QP-301TH. Weighing approximately 190 pounds, it features built-in wheels and a comfortable handle that make transport and maneuvering straightforward, making it a practical choice for job sites, camping, or tailgating.

Moreover, the generator incorporates several advanced technologies to enhance performance and safety. The low-noise operation, a hallmark of Multiquip generators, ensures a quieter working environment, while the automatic shut-off feature protects the engine from damage in case of low oil levels.

The protective frame provides durability and safeguards the generator against accidental impacts. It is also designed to withstand various weather conditions, making it suitable for outdoor use.

Overall, the Multiquip QP-301TH stands out due to its combination of power, efficiency, and portability. Its user-centric design and advanced safety features make it a desirable choice for those looking for a dependable generator to handle their energy needs. Whether for professional use or recreational activities, the QP-301TH is a reliable power solution.