MAINTENANCE (ENGINE)

SPARK ARRESTER CLEANING

Clean the spark arrester every 6 months or 100 hours.

1.Remove the 4 mm screw (3) from the exhaust deflector, then remove the deflector. See Figure 22.

2.Remove the 5 mm screw (4) from the muffler protector, then remove the muffler protector.

3.Remove the 4 mm screw from the spark arrester, then remove the spark arrester

Figure 22. Spark Arrester Removal

4.Carefully remove carbon deposits from the spark arrester screen (Figure 23) with a wire brush.

WIRE

BRUSH

SPARK

ARRESTER

SCREEN

Figure 23. Cleaning The Spark Arrester

5.If the spark arrester is damaged and has breaks or holes, replace with a new one.

6.Reinstall the spark arrester and muffler protector in reverse order of disassembly.

PAGE 24 — QP3TH TRASH PUMP • OPERATION AND PARTS MANUAL — REV. #8 (01/29/14)

Page 24
Image 24
Multiquip QP3TH manual Spark Arrester Cleaning, Spark Arrester Removal