Multiquip STX55Y6 operation manual Stx-Series- Maintenance, Checking Hydraulic Pressure

Models: STX55Y6

1 48
Download 48 pages 62.45 Kb
Page 40
Image 40
Checking Hydraulic Pressure

Checking Hydraulic Pressure

1Pressure Guage - 5,000 PSI Range WARNING

NEVER use your hand to find hydraulic leaks. Use a piece of wood or cardboard. Hydraulic fluid injected into the skin must be treated by a knowledgable physician immediately or severe injury or death can occur.

Many hydraulic problems are a result of low fluid levels. Before checking any other possibilities, make sure the hydraulic fluid level is up to the top of the sight glass which is located at the back/center of the frame.

Hydrostatic pressure can be checked using a pressure gauge with a range of at least 5,000 psi. Two male diagnostic quick couplers (one for each pump) are located beneath the right grill guard. To access couplers (Figure 41), remove the grill guard. It is best to use two gauges simultaneously (Figure 40), but it is possible to use only one gauge and repeat the procedure for each side.

1

 

2000

3000

 

1000

150

200

4000

 

100

250

 

 

50

300

 

bar

psi 5000

WIKA

4

STX-SERIES — MAINTENANCE

To fully test the hydrostatic system, the spiders will need to be locked so that they cannot rotate.This can be done by wrapping a chain around an arm on each spider, thus chaining them together in the back of the trowel.

Once the pressure gauges are installed and the spiders chained together, the system can be checked.

With the foot pedal in the idle position and the engine at full speed, the pressure should be 200 to 300 psi. If the pressure is less than 200 psi, the charge system may need to be inspected and/ or serviced.In particular, the suction filter and charge pump relief valve should be checked.The suction filter may be plugged, or the relief valve may be stuck. Either condition may cause low charge pressure.

With the engine at 50% to 70% of full speed, and spiders chained together, slowly depress the foot pedal and read the gauges. The pressure should get to at least 4,350 psi (300 bar). If the pressure will not attain 4,350 psi (300 bar), the pump should be inspected and/or serviced by an authorized service representative.

 

2000

3000

 

1000

150

200

4000

 

100

250

 

1

50

300

 

 

bar

5000

 

 

psi

 

 

 

WIKA

3

2

1Pressure Guage - 5,000 PSI Range

2Parker Hannifin Quick Disconnect PD-Series Diagnostic Female Coupler

3Right Side Hydrostatic Pump Test Port

4Left Side Hydrostatic Pump Test Port

Figure 40. Pressure Gauge (Hydraulic Pump)

PAGE 40 — STX-SERIESRIDE-ON POWER TROWEL — OPERATION MANUAL — REV. #0 (03/15/06)

Page 40
Image 40