Multiquip STX55Y6 Stx-Series- Troubleshooting, Troubleshooting Continued, Symptom, Solution

Models: STX55Y6

1 48
Download 48 pages 62.45 Kb
Page 45
Image 45
STX-SERIES — TROUBLESHOOTING

STX-SERIES — TROUBLESHOOTING

TABLE 5. TROUBLESHOOTING (CONTINUED)

SYMPTOM

POSSIBLE PROBLEM

SOLUTION

 

 

 

 

 

Check all electrical connections, including the master on/off switch

 

Wiring?

and check to see if wiring is in good condition with no shorts.

 

Replace as necessary.

Lights (optional) not working.

 

 

 

 

 

 

 

Lights?

Check to see if light bulbs are still good. Replace if broken.

 

 

 

 

 

Check the tank to make sure retardant is present. Fill tank as

 

Retardant?

necessary.

 

 

 

 

 

Check all electrical connections, including master on/off switch

 

Wiring?

connections. Replace components and wiring as necessary.

Retardant spray (optional) not

 

 

working.

Bad switch?

Check the continuity of master on/off switch. Replace if broken.

 

 

 

 

 

 

 

 

If pump has a voltage present when the switch is turned on, but

 

Bad spray pump?

does not operate and electrical connections to the pump are

 

good, replace the pump.

 

 

 

 

 

 

Blade speed out of adjustment?

See section on blade speed adjustment.

 

 

 

 

 

 

 

Check for wear of steering bearings and linkage components

 

Worn components?

replace if necessary.

Steering is unresponsive.

 

 

Pivots?

Check to ensure free movement of hydraulic drive motors.

 

 

 

 

 

 

 

Hydraulic pressure?

Check to ensure that hydraulic steering pressure is adequate. See

 

section on checking hydraulic steering pressure.

 

 

 

Operating position is

Seat adjust for operator?

Adjust seat with lever located on the front of the seat.

uncomfortable.

 

 

 

 

 

 

 

Wiring?

Check and repair wiring and connectors as necessary.

Pitch System not working.

 

 

Spool stuck in solenoid valve?

Replace solenoid valve.

 

 

 

 

 

 

STX-SERIESRIDE-ON POWER TROWEL — OPERATION MANUAL — REV. #0 (03/15/06) — PAGE 45

Page 45
Image 45
Multiquip STX55Y6 Stx-Series- Troubleshooting, Troubleshooting Continued, Symptom, Possible Problem, Solution