OPLH / OPLHA Series
Specifications
Enclosure Type (die cast aluminum)
•Surface mount, square case
•Panel mount, round case
•Panel mount, square case
Limit Switch Ratings
•Pointer Contacts: SPDT center off; 2 A, 30 VDC, 1 A, 125 VAC.
Latching Control Relay
•SPDT,10 A @ 120 VAC (standard)
•DPDT, 12 VDC (Optional)
•DPDT, 24 VAC (Optional)
•DPDT, 24 VDC (Optional)
Sensing Element
•Bourdon Tube, Bronze/Brass (standard)
•Bellows, 316 Stainless Steel (standard)
Process Connections
•1/4 NPT Male
•1/4 NPT Female
•2 NPT Male
Geared Movement: 300 series stainless steel.
Accuracy (standard calibration is for water)
•±2% first/last quarters of scale, 1% middle half scale. (1)
•3% full scale.
OPTIONS AVAILABLE (specify when ordering)
•Environment sealed for isolation from the elements (ES). (2)
•
•
•Less case; internal gage mechanism without case (LC)
•Tickler contact (TA)
RANGES AVAILABLE (specify when ordering)
•
•
•
•
•
•
•
•
•
•
OPLHFCOPLHCEOPLHACS | OPLHACES | OPLHABPES | OPL | OPL | OPL | OPL | |
OPLHBPOPLHABPSOPLHBPE | OPLHGOPL |
|
| ||||
|
|
|
| HFG | HAGS HAGES HAFCS HAFGS |
(1)Bourdon tube (OPLHC) models in the 20 ft. (6 m) range have an accuracy of 3% full scale.
(2)ES option available for the 20 ft. (6 m) range models and above.
NOTES:
•Options may not be available in combination. Consult factory.
•Over range is not to exceed 10% FS above full range.
•Calibration is for water. Specify for other liquids.
•Add TOTAL height of liquid above the pressure connection to determine correct range (dial scale). For elevated tanks substract the tank elevation from gage reading to determine actual tank level.
Shipping Dimensions
Item Dimensions: 16 x 11 x
Explosion-proof models: 12 x 12 x 9 in. (305 x 305 x 229 mm).
Shipping Weights
Item Weight: 8 lb. (3.6 kg) approximately.