Dimensions
Surface / Panel Mount Enclosure (Square Case)
(102 mm)
Mounting Holes 9/32 in. (7 mm) diameter 3 places. Not available on panel mount square case.
(214 mm)
(200 mm)
1/2 NPT conduit
NOTE: Panel mount
square case models do not include mounting flange and include bolt circle shown in Panel Mount Enclosure versions (see below).
Process Connection 1/4 NPT male on
bourdon tube models
and 1/4 NPT female Surface on bellows models.
Panel Mount Enclosure
(Round Case)
Explosion-proof Enclosure (“EX” Option)
8 in. | ||
7/8 in. (22 mm) | ||
(203 mm) |
| deep, 4 places. |
1/4 in. (6 mm) dia. holes (3 places.)
on
(bolt circle),120 apart, clocking as shown
Mounting Hole
| |
(138 mm) | (73 mm) |
120 |
|
120 |
|
Panel |
|
Process Connection |
|
1/4 NPT Male. |
|
(171 mm) | (162 mm) | |
|
| 1/2 NPT |
8 in. |
| optional |
| rear or side | |
(203 mm) |
| conduit |
|
| |
(171 mm) |
|
|
| Removable lid | Rear mounting holes |
Mounting Hole | for surface mounting | |
to access adjustable | ||
diameter. Not required | contact knobs. | 7/8 in. (22 mm) |
for surface mounting. | Process Connection | deep, 4 places. |
1/4 NPT Female
Above Ground Tank
Tank
SWICHGAGE®
Head
Pressure
Typical Applications
Below Ground Tank
| Flow regulator | Pressure |
| regulator | |
| (recommended) |
|
Pressure | SWICHGAGE® | Air compressor |
regulator |
|
|
Air compressor |
|
|
| Ground surface |
|
Flow regulator
(recommended)Underground tank (vented)
Direct and Remote Tank
Tank
Direct Mount
SWICHGAGE®
Remote
SWICHGAGE® with Sensing Line Underground
1 foot