Service Parts

DESCRIPTION (see drawing–right)

PD8183

PD8184

PD8185

PD8190

A. 1/2 NPT inlet x 1/4 NPT outlet*

65-05-0104

65-05-0210

65-05-0204

65-05-1136

1/2 NPT inlet x 1/2 NPT outlet*

65-05-0105

65-05-0212

65-05-0206

65-05-1135

B. Bonnet Fitting

65-05-0099

65-05-0209

65-05-0203

65-05-1139

C. Valve Stem

65-05-0175

65-05-0208

65-05-0202

65-05-1140

D. Packing Nut

65-05-0098

65-05-0211

65-05-0205

65-05-1137

E. Hand Wheel (with 10-32 nut)

55-00-0179

55-00-0179

55-00-0179

55-00-0179

F. Strainer Bushing Assembly

55-00-0174

55-00-0173

55-00-0175

55-00-0206

G. Molded Packing Gland

00-00-0936

00-00-0936

00-00-0936

00-00-0936

H. ‘O’ Ring Bonnet Seal

00-00-0302

00-00-0302

00-00-0302

00-00-0302

J. Stainless Steel Mesh Filter**

65-05-0214

65-05-0214

65-05-0214

65-05-0214

Provided only for units with 1/4 NPT inlet.

*For 1/4 NPT inlet use with strainer bushing assembly. **Provided in units with 1/2 NPT inlet.

C

D

A B

INLET

FJ

E

G

H

OUTLET

Dimensions

3-7/8 in.

(99 mm)

FLOW

3in.

(76 mm)

Mounting for the OPLFC Pressure SWICHGAGE® and PD8100 Series

The PD8100 Series pulsation dampener is mounted directly below the OPLFC.

Precautions: Dope or use teflon tape on con- nection threads. Do not block the inlet orifice.

 

4-3/4 in.

OPLFC

(121 mm)

diameter

Mounting

 

Hole

How to Order

PD8185 - 1/4 x 1/4

Base Model

PD8183

PD8184

PD8185

PD8190

Connection Size

1/4 x 1/4 = 1/4 NPT inlet x 1/4 NPT outlet 1/4 x 1/2 = 1/4 NPT inlet x 1/2 NPT outlet 1/2 x 1/2 = 1/2 NPT inlet x 1/2 NPT outlet 1/2 x 1/4 = 1/2 NPT inlet x 1/4 NPT outlet

Shown at right, is a typical MURPHYMATIC® compres- sor panel featuring three Pulsation Dampeners and

1/4 in. (6 mm) dia. holes (3 pls.) on

5-13/64 in. (132 mm) B.C.,120° apart, clocking as shown

PD8100

 

2 in.

Series

 

(51 mm)

Mounting

Hole

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5-5/16 in.

(135 mm)

1/2 in. radius typical

1in.

(25 mm)

Murphy’s OPLFC gages.

The PD's are recommended for use on piston pumps and compressors to eliminate pointer contact flutter

and gage wear.

FW Murphy

P.O. Box 470248

Tulsa, Oklahoma 74147 USA +1 918 317 4100

fax +1 918 317 4266 e-mailsales@fwmurphy.com www.fwmurphy.com

CONTROL SYSTEMS & SERVICES DIVISION P.O. Box 1819; Rosenberg, Texas 77471; USA +1 281 633 4500 fax +1 281 633 4588 e-mail sales@fwmurphy.com

MURPHY DE MEXICO, S.A. DE C.V.

Blvd. Antonio Rocha Cordero 300, Fracción del Aguaje San Luis Potosí, S.L.P.; México 78384

+52 444 8206264 fax +52 444 8206336 Villahermosa Office +52 993 3162117 e-mailventas@murphymex.com.mx www.murphymex.com.mx

FRANK W. MURPHY, LTD.

Church Rd.; Laverstock, Salisbury SP1 1QZ; U.K. +44 1722 410055 fax +44 1722 410088 e-mailsales@fwmurphy.co.uk www.fwmurphy.co.uk

MURPHY SWITCH OF CALIFORNIA

41343 12th Street West

Palmdale, California 93551-1442; USA

+1 661 272 4700 fax +1 661 947 7570 e-mailsales@murphyswitch.com www.murphyswitch.com

MACQUARRIE CORPORATION 1620 Hume Highway Campbellfield, Vic 3061; Australia

+61 3 9358 5555 fax +61 3 9358 5558 e-mailmurphy@macquarrie.com.au

 

E

 

 

D

 

 

 

 

R

 

 

 

 

 

 

E

 

 

GISTER

 

 

 

 

 

 

USA–ISO 9001:2000 FM 28221

UK–ISO 9001:2000 FM 29422

In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications and designs at any time.

Printed in U.S.A.

PD-95145B page 2 of 2

Page 2
Image 2
Murphy PD8100 Series specifications Service Parts, Dimensions, How to Order