Swichgage® Shutdown Panels with Open Back for Diesel Engines

Swichgage® Shutdown Panels with Open Back for Diesel Engines

WD-03061B

Revised 04-06

Catalog Section 30

WD300-LV

WD300 Series

Universal Design Ideal for Diesel Engines Without Fuel Solenoid Built Into the Injection Pump

Swichgage Instruments for Low Oil Pressure, High Coolant Temperature
Includes Fuel Solenoid Shutdown Valve

Description

WD300 Series

The universally applicable WD300 Series panels are the ideal control solution for a wide variety of diesel engines without shut- down solenoid in the injection pump.

The standard WD300 Series panel includes basic engine protection for low oil pressure and high coolant temperature. It also includes Murphy’s SV Series solenoid fuel shut-off valve, (see bulletin SV-99026B).

WD300LV Models

For engines that have the fuel shut-off sole- noid built into the injection pump. This model also applicable to battery ignition engines.

Panel Kits Include:Low Lube Oil Pressure Swichgage instrument.High Coolant/ Temperature Swichgage instrument.

117PH Magnetic Switch.

SV Series Solenoid Fuel Shutoff Valve.PB128S Emergency Stop Push Button.SpecificationsLow Lube Oil Pressure SWICHGAGE®:0-100 psi (0-689 kPa) [0-6.89 bar]

1/8 NPT process connection

High Coolant SWICHGAGE®:130-250°F (54-121°C)

48 in. (1.2 m) capillary

1/2 NPT process connection117PH Magnetic Switch

SV Series Solenoid Fuel Shutoff Valve:

12 or 24 volt (specify)

Shipping Weight: 8 lbs. 8 ozs. (3.9 kgs.)

Shipping Dimensions:8.5 x 5.25 x 5.5 in. (216 x 133 x 140 mm).Warranty

A limited warranty on materials and workmanship is given with this FW Murphy product. A copy of the warranty may be viewed or printed by going to www.fwmurphy.com/support/warranty.htm

 

 

 

 

 

 

 

 

5-1/8 in. (130 mm)

 

 

3-5/8 in. (92 mm)

 

 

 

 

 

 

 

 

 

 

 

 

WD300-LV 6-3/4 in. (171 mm) WD300 Series■Swichgage Instruments for Low Oil Pressure, High Coolant Temperature 6-1/8 in. (156 mm) ■Includes Fuel Solenoid Shutdown Valve

20T250-4-1/2 Temperature Swichgage®

20P100

Oil Pressure Swichgage®

PB128S Emergency 117PH Magnetic Switch Stop Push Button

Dimensions (all Models)

NOTE: This is an standard schematic. If non-standard components are specified, this schematic may not exactly reflect your panel.

in. (97 mm)

(78 mm)

 

-313/16

1/16-3 in.

shipped loose

 

 

1/2-14 NPT

Adapter Nut

WD-03061B page 1 of 2