Musical Fidelity A5 CR manual Problems ?, Probable Cause, Remedy

Models: A5 CR

1 7
Download 7 pages 25.42 Kb
Page 6
Image 6
PROBLEMS ?

PROBLEMS ?

Basic problem-solving with an amplifier is similar to troubleshooting other electrical or electronic equipment. Always check the most obvious possible causes first, such as the following examples:

Problem

Probable Cause

Remedy

 

 

 

No power when POWER

Mains power plug is not fully

Plug in securely

button is pressed

inserted into rear socket

 

 

 

 

No sound

Tape monitor function has been

Switch off tape monitor

 

selected on the pre-amplifier

 

 

 

 

 

Wrong connections between

Check audio input lead

 

input source and the A5 Power

connections

 

 

 

 

Speakers not connected, or

Check speaker cables

 

incorrectly wired

 

 

 

 

Sound is not precise, lacking in

Speakers are connected out of

Ensure speakers are connected

bass and stereo image

phase, i.e., connections to one

correctly

 

speaker (+ and -) are reversed

 

 

 

 

Hum

Audio connector plug not fully

Insert plug securely

 

pushed in

 

 

 

 

If none of these actions effect a cure, please contact your dealer, or an authorised Musical Fidelity service agent. Remember, never open the case of the A5 CR Power amplifier yourself, as this will invalidate the guarantee.

Issue 1 : November 2004

A5 CR Power Amplifier

Instructions for use

Page 6 of 7

Page 6
Image 6
Musical Fidelity A5 CR manual Problems ?, Probable Cause, Remedy