Inflatable PFD Re-Arm Kit MA7214
WARNING
·Use only with specified PFD models.
·This gas cylinder is under pressure, therefore misuse can be dangerous.
·Do not incinerate, expose to sunlight or store above 120˚F (50˚C).
·Do not throw into open fire or dump at sea.
·Keep away from children.
·Dispose of gas cylinders only when empty.
·Discharge and dispose of corroded or rusty cylinders.
IMPORTANT: Please review and follow additional maintenance instructions in your manual.
Re-arming instructions
CAP | Figure 3 |
4Squeeze the sealing ring to elongate and remove the inflator body through the sealing ring (Fig. 4).
RED INDICATOR
INFLATOR BODY
WATER |
INLET VALVE |
SINGLE |
POINT INDICATOR |
Figure 7 |
8Hold the CO2 cylinder through the fabric of the Inflatable PFD (Fig 8a). Position the replacement cap with the water inlet valve pointing to the right and press firmly onto the inflator body and sealing ring (Fig. 8b).
tube and check that it stays inflated at least overnight. Empty the Inflatable PFD again by reversing the oral- inflation tube dust cap and inserting it into the valve. Gently squeeze the inflatable PFD until all air or gas has been expelled. Let the Inflatable PFD dry before packing.
IMPORTANT: Ensure all air is removed before repacking.
13 Refold the Inflatable PFD in accordance with the repacking section in the PFD manual.
1Place the Inflatable PFD (Personal Flotation Device) on a smooth, flat surface and wipe off any water.
If needed, unpack the PFD starting at the zipper flap. Access the inflator by reaching between the cover and cell and pull it toward you, turning the cell and cover inside out to fully expose the inflator for
Figure 1 |
SEALING RING
Figure 4
5Dispose of the used inflator body (Fig. 5).
RED INDICATOR |
TRASH |
Figure 5 |
| 90º |
Figure 8a | Figure 8b |
9While pressing FIRMLY onto the inflator body, turn the BLACK locking ring clockwise into the locked position (Fig. 9). Pull on the cap to make sure it has locked onto the inflator body.
PA7214_Rearm_12Aug2009.indd
2Insert the metal key between the black locking ring and labeled yellow cap. Turn the key
LOCKING RING | KEY | Figure 2 |
3Turn the black locking ring
6Check that the new inflator body indicator is green. Insert
the new inflator body with CO2 cylinder pointing upward inside the Inflatable PFD. Let the sealing ring rest on the adapter around the four lugs (Fig. 6).
GREEN | CAUTION: |
INDICATOR | |
| DO NOT TURN |
| THE CENTER |
| SHAFT |
| Figure 6 |
7Now check the new manual/automatic cap as follows (Fig. 7):
1.Is the single point status indicator showing green?
2.Is the expiry date OK?
If YES is the answer to both questions, then proceed as follows. If the answer is NO to either question, get a new cap.
BLACK | Figure 9 |
LOCKING RING |
10 Check: To see that the single point status indicator on the cap is green; the pull to inflate lanyard is present and that the locking ring is locked.
11 Turn cell and cover
that the single point status
indicator is visible thrrough the inflator cap cover window.
12 If your Inflatable PFD has been used and/or the inflator replaced, always inflate through the oral