MUSTANG SURVIVAL MA4013
Inflatable PFD Re-arm Kit
VFI Gonflable Ensemble De Réarmement
V.F.I. de MUSTANG SURVIVAL:
MD4020
Inflatable PFD Re-Arm Kit MA4013
WARNING
·Use only with specified PFD models.
·This gas cylinder is under pressure, therefore misuse can be dangerous.
·Do not incinerate, expose to sunlight or store above 120˚F (50˚C).
·Do not throw into open fire or dump at sea.
·Keep away from children.
·Dispose of gas cylinders only when empty.
·Discharge and dispose of corroded or rusty cylinders.
IMPORTANT
Please review and follow additional maintenance instructions in your Owner’s Manual.
The Damage Tolerant Life Preserver is equipped with two cylinders. Please inspect both to ensure proper operation.
Re-arming instructions
Figure 1
1. Place the Inflatable PFD on a smooth, flat |
surface and wipe off any water. Access the |
inflator by reaching under the cover and pull |
CAP | Figure 3 |
3.Turn the black locking ring
RED
INDICATOR
INFLATOR BODY
SEALING RING
Figure 4
4.Squeeze the sealing ring to elongate and remove the inflator body through the sealing ring (Fig. 4).
RED INDICATOR |
TRASH |
Figure 5 |
5. Dispose of the used inflator body (Fig. 5).
WATER |
INLET VALVE |
SINGLE |
POINT INDICATOR |
Figure 7 |
7.Now check the new manual/automatic cap as follows (Fig. 7):
1.Is the single point status indicator showing green?
2.Is the expiry date OK?
If YES is the answer to both questions, then proceed as follows.
If the answer is NO to either question, get a new cap.
| 90º |
Figure 8a | Figure 8b |
8.Hold the CO2 cylinder through the fabric of the Inflatable PFD (Fig 8a). Position the replacement cap with the water inlet valve pointing to the right and press firmly onto the inflator body and sealing ring (Fig. 8b).
11.If your Inflatable PFD has been used and/or the inflator replaced, always inflate through the oral tube and check that it stays inflated at least overnight. Empty the Inflatable PFD again by reversing the
IMPORTANT: Ensure all air is removed before repacking.
12.Refold the Inflatable PFD in accordance with the Repacking section of the owner’s manual.
it toward you, turning the cell and cover inside |
out to fully expose the inflator for |
At this time, ensure that the inside of the |
bladder is dry. Hold the CO2 cylinder through |
the fabric, using one hand (Fig. 1). |
GREEN |
INDICATOR |
CAUTION: DO NOT TURN THE CENTER SHAFT
Figure 6
BLACK | Figure 9 |
LOCKING RING |
9. While pressing FIRMLY onto the inflator body, |
turn the BLACK locking ring clockwise into the |
2.Insert the metal key between the black locking ring and labeled yellow cap. Turn the key
6.Check that the new inflator body indicator is
green. Insert the new inflator body with CO2 cylinder pointing upward inside the Inflatable PFD. Let the sealing ring rest on the adapter around the four lugs (Fig. 6).
locked position (Fig. 9). Pull on the cap to make |
sure it has locked onto the inflator body. |
10. Check: To see that the single point status |
indicator on the cap is green; the pull to |
inflate lanyard is present and that the locking |
ring is locked. |
PA4013_Rearm_10Apr2007.indd
4/26/2007 4:15:19 PM