LED’s: The table below describes the operating modes:

LED

Color

Description

 

GREEN

Power is Applied

 

 

 

 

OFF

Power is OFF

 

 

 

!

RED

Controller HW Error

 

 

 

 

 

 

OFF

No Errors. Normal

 

 

Operation.

 

 

 

LNK

GREEN

Link between ports

 

established

 

 

 

 

 

 

OFF

No Link between ports

 

 

 

ACT

GREEN

Data is active between

 

ports

 

 

 

 

OFF

Data is inactive between

 

 

ports

 

 

 

APPLYING POWER (Side View)

Unscrew & Remove the DC Voltage Input Plug(s) from the side header Install the DC Power Cables into the Plug(s) (observing polarity).

Plug the Voltage Input Plug(s) back into the side header.

Tightening torque for the terminal block power plug is 0.22 Nm/0.162 Pound Foot. All LED’s will flash ON Momentarily (including the Error LED)

Verify the Power LED stays ON (GREEN). Verify the Error LED is OFF (after a few seconds).

Note: Only 1 plug is required to be connected to power input for minimal operation. For redundant power operation, V1 and V2 plugs must be connected to separate DC Voltage sources. Use wire sizes 16-28 gauge.

Recommended 24V DC Power Supplies, similar to 100VAC/240VAC:

N-Tron’s NTPS-24-1.3, DC 24V/1.3A

Rev 102507

10

Page 10
Image 10
N-Tron 400 manual Led, Color Description, Applying Power Side View