Nady Systems owner manual Applications, Specifications, USING THE PRA-8

Models: PRA-8

1 8
Download 8 pages 10.93 Kb
Page 6
Image 6
APPLICATIONS

APPLICATIONS

USING THE PRA-8

It is as simple as ABC to use and operate the PRA-8. Each of the eight pre-amplifier channels has its own INPUT (1) and OUTPUT (5) and variable GAIN (2) control.

A. Connect a signal you wish to process to one of the XLR balanced INPUTS (1) on the front of the PRA-8.

B. Connect the corresponding channel OUTPUT (5) on the rear of the PRA-8 to your desired destination (mixer, recorder, etc).

C. Adjust the variable GAIN (2) control of that channel to the desired pre-amplified level. To ensure that you do not over pre- amplify your signal, a PEAK (CLIP) LED INDICATOR (9) has been provided on the front panel of the PRA-8 for each channel. When illuminated, this LED indicates that the pre-amplifier for that channel is overloaded and that distortion may result. Turn down the variable GAIN (2) control for the selected channel until the PEAK (9) LED is no longer illuminated.

SPECIFICATIONS

AUDIO INPUTS & PRE AMPS

 

Connectors

XLR

Type

Balanced

Impedance

2k Ohms

Min Sensitivity

-40dB

Peak input level

+5dB

Gain control range

50dB

Peak amplification

74dB

Phantom power

+48V, switchable

AUDIO OUTPUTS

 

Connectors

1/4" jack

Type

TRS Balanced

Impedance

600 Ohms

Peak output level

+18.5dB

DISTORTION, FREQUENCY RESPONSE,

S/N RATIO & CROSSTALK

 

Frequency response

20Hz~20kHz, 0dB~-2B

Distortion

0.02%

S/N Ratio

Better than 80dB

Crosstalk rejection

>70dB@1kHz; -20dB input

POWER SUPPLY

 

Power Requirements

selectable, ~ 100-120 VAC,

 

~ 200-240 VAC, 50-60 Hz

Fuse

100-120 VAC: 630 mA (slow-blow)

 

200-240 VAC: 315 mA (slow-blow)

 

100-240 VAC: 500 mA (slow-blow)

 

5X20mm glass type

Power cord connector

Standard IEC receptacle

 

with built-in fuse holder

PHYSICAL

 

Dimensions

1.75"X 19"X 8.5” (44.5X482.6X217mm)

Weight

7.48lbs (3.4Kg)