13

INSTALLATION

WALL AND CEILING PROTECTION

FOR SAFEAND PROPER OPERATION OF THE FIREPLACE, FOLLOW THE VENTING INSTRUCTIONS EXACTLY.

VERTICAL INSTALLATION

NOTE: Only a clearance to combustibles of 1" all around the vent pipe is required.

HORIZONTAL INSTALLATION

This application occurs when vent- ing through an exterior wall. Having determined the air terminal location, cut and frame a hole in an exterior wall with a minimum opening as

This application occurs when venting through a roof. Installation kits for various roof pitches are available from your Napo- leon dealer. See Accesso- ries to order the specific kit required.

FIGURE 16

required. See Note above. (As an alternative to framing, a vent pipe shield may be installed, ensuring a 1" clearance to combustibles.

See Figure 16.)

FIGURE 14

1.Mark and cut the vent pipe shield to the determined depth of the combustible wall. Apply a bead of caulking (not supplied) to the framework or to the shield plate (in the case of a finished wall) and secure the shield through the opening to the interior wall. The final location of the vent pipe shield should maintain the required clearance to the 8" vent pipe / liner. (See note above). Do not fill this cavity with any type of material. Apply a bead of caulking all around and place a firestop spacer over the vent shield to restrict cold air from being drawn into the room or around the fire- place. Ensure that both spacer and shield maintain the required clearance to combustibles. Once the vent pipe / liner is installed in its final position, apply sealant between the pipe / liner and the firestop spacer.

OR

FIGURE 15

1.Determine the air terminal location, cut and frame 10 inch openings in the ceiling and the roof to provide the minimum 1 inch clearance between the fireplace pipe / liner and any combustible material. Try to center the ex- haust pipe location midway between two joist to prevent having to cut them. Use a plumb bob to line up the center of the openings. DO NOT FILL THIS SPACE WITH ANY TYPE OF MATERIAL. A vent pipe shield will prevent any materials such as insulation, from filling up the 1" air space around the pipe. Nail headers

between the joist for extra support.

2.Apply a bead of FIGURE 17

caulking (not sup- plied) to the frame- work or to the Wolf

Steel vent pipe shield plate or equivalent (in the case of a finished ceiling), and secure over the opening in the ceil- ing. FIGURE 18. A firestop must be placed on the bottom of each framed opening in a roof or ceiling that the venting system passes through. Apply a bead of caulking all around and place a firestop spacer over the vent shield to restrict cold air from being drawn into the room or around the fire- place. Ensure that both spacer and shield maintain the required clearance to combustibles. Once the vent pipe / liner is installed in its final position, apply sealant between the pipe / liner and the firestop spacer.

W415-0381 / E / 02.09.06

Page 13
Image 13
Napoleon Fireplaces BGD42P manual Installation Wall and Ceiling Protection, Vertical Installation Horizontal Installation

BGD42P specifications

Napoleon Fireplaces has long been recognized for their commitment to quality, style, and innovation in home heating solutions. Among their impressive lineup, the BGD42P and BGD42N models stand out, showcasing exceptional features and advanced technologies that make them a popular choice for both aesthetics and functionality.

The BGD42P is a contemporary gas fireplace designed to provide a sleek, modern look for any living space. It features an impressive 42-inch viewing area, allowing for a magnificent fire display that becomes the focal point of any room. This model includes a high-efficiency burner, which not only produces a stunning flame but also ensures that the warmth is evenly distributed throughout the space. The BGD42P uses a direct vent system, providing safe and efficient venting, which eliminates the need for a traditional chimney and minimizes heat loss.

On the other hand, the BGD42N offers a more traditional appearance, making it an excellent choice for those who prefer classic design elements. Like its counterpart, it boasts a 42-inch viewing area and a high-efficiency burner. However, the BGD42N incorporates a realistic log set, enhancing its traditional appeal while still delivering exceptional heat output and efficiency. Both models are equipped with Napoleon's advanced electronic ignition system, ensuring quick and reliable starts even during power outages.

One of the standout technologies featured in both models is the proprietary PHAZER log set. This innovative design enhances the realism of the flame presentation, resembling a natural wood-burning fire. Additionally, Napoleon’s exclusive heat management system allows users to maximize comfort while minimizing energy consumption.

Both fireplaces come with customizable options, including a variety of decorative media such as river rocks or glass beads, allowing homeowners to personalize their space to match their unique style. Furthermore, Napoleon offers optional remote controls, making operation effortless.

In summary, the BGD42P and BGD42N models from Napoleon Fireplaces exemplify the company’s dedication to delivering high-quality, stylish, and efficient home heating solutions. With a blend of modern technology and classic design elements, these fireplaces not only provide warmth but also enhance the ambiance of any living area. Whether you lean towards contemporary or traditional aesthetics, Napoleon's offerings are sure to meet and exceed expectations, making them a worthwhile investment for any homeowner.