W415-0381 / E / 02.09.06
FIGURE 27
AIR INLET BASE

5.Remove nails from the shingles, above and to the sides of the chimney. Place the flashing over the air terminal connector leaving a min. 3/4” of the air terminal connector showing above the top of the flashing. Slide the flashing underneath the sides and upper edge of the shingles. Ensure that the air terminal connector is properly centred within the flashing, giving a 3/4” margin all around. Fasten to the roof. Do not nail through the lower portion of the flashing. Make

weather-tight by sealing with caulking. Where possible, cover the sides and top

edges of the flashing with roofing

material.2”

6. Aligning the seams of the

CAULKING

terminal and air terminal connector,

STORM COLLAR

place the terminal over the air

 

terminal connector making sure the

WEATHER

SEALANT

liner goes into the hole in the

 

terminal. Secure with the three

FLASHING

screws provided.

Spacers are

7. Apply a heavy bead of

attached to the inner

weatherproof caulking 2 inches

flex liner at

predetermined

above the flashing. Note: Maintain a

intervals to maintain

minimum 2” space between the air

a 1-1/4” air gap to

inlet base and the storm collar.

the outer flex liner.

These spacers must

Install the storm collar around the air

not be removed.

terminal and slide down to the caulking. Tighten to ensure that a weather-tight seal between the air terminal and the collar is achieved.

15

7.If more liner needs to be used to reach the fireplace, couple them together as illustrated. The vent system must be supported approximately every 3 feet for both vertical and hori- zontal runs. Use noncombustible strapping to maintain a clearance to combustibles of 1".

FIREPLACE VENT CONNECTION

1.Install the 5 inch diameter aluminium flexible liner to the fireplace. Secure with 3 screws and flat washers. Seal the joint and screw holes using the high temperature seal- ant Mill Pac.

2.Install the 8 inch diameter aluminium flexible liner to the fireplace. Attach and seal the joints.

FIGURE 24

USING RIGID VENT COMPONENTS

The vent system must be supported approximately every 3 feet for both vertical and horizontal runs. Use Wolf Steel vent spacers every 3 feet and either side of each elbow to maintain the minimum 1¼" clearance between the outer and inner vent pipes. Use Wolf Steel support ring assem- bly or equivalent noncombustible strapping to maintain the minimum clearance to combustibles for both vertical and horizontal runs.

All inner exhaust and outer intake vent pipe joists may be sealed using either Red RTV high temp silicone seal- ant or Black high temp Mill Pac with the exception of the fireplace exhaust flue collar which must be sealed us- ing Mill Pac (not supplied).

HORIZONTAL AIR TERMINAL INSTALLATION

FIGURE 25

1.Move the fireplace into po- sition. Measure the vent length required between terminal and fireplace taking into account the

additional length needed for the finished wall surface and any 1¼" overlaps between venting components.

2.Apply high temperature sealant Mill Pac to the outer edge of the 5" inner collar of the fireplace. Attach the first vent compo- nent and secure using 3 self tapping screws. Repeat using 8" piping.

3. The heat shield must be

FIGURE 26

installed only when terminat-

 

ing horizontally with no verti-

 

cal rise. Remove the two

 

screws nearest the vent col-

 

lars on the top of the fireplace.

 

Align the vent shield (sup-

 

plied) and secure.

 

4.Holding the air terminal (with the air deflectors to the top), insert into both vent pipes with a twisting motion to ensure that both the terminal sleeves engage into the vent pipes and sealant. Secure the terminal to the exterior wall and make weather tight by sealing with caulking (not supplied).

The air terminal mounting plate may be recessed into the exterior wall or siding by 1½", the depth of the return flange.

EXTENDED HORIZONTAL AIR TERMINAL

INSTALLATION

1.Follow the instructions for "Horizontal Air Terminal In-

stallations", items 1 to 3.

2.Continue adding compo- nents alternating inner and outer venting. Ensure that all 5" venting and elbows have suffi- cient vent spacers attached and each component is securely

fastened to the one prior. Attach the 5" telescopic sleeve to the vent run.

Repeat using a 8" telescopic sleeve. Secure and seal as before. To facilitate completion, attach 5" and 8" couplers to the air terminal.

3.Install the air terminal. See item 3 of the

Horizontal Air Terminal Installation. Extend the 5" telescopic sleeve; connect to the air terminal assembly. Fasten with self tapping screws and seal. Repeat using the 8" tel- escopic sleeve.

Page 15
Image 15
Napoleon Fireplaces BGD42P manual Using Rigid Vent Components, Fireplace Vent Connection

BGD42P specifications

Napoleon Fireplaces has long been recognized for their commitment to quality, style, and innovation in home heating solutions. Among their impressive lineup, the BGD42P and BGD42N models stand out, showcasing exceptional features and advanced technologies that make them a popular choice for both aesthetics and functionality.

The BGD42P is a contemporary gas fireplace designed to provide a sleek, modern look for any living space. It features an impressive 42-inch viewing area, allowing for a magnificent fire display that becomes the focal point of any room. This model includes a high-efficiency burner, which not only produces a stunning flame but also ensures that the warmth is evenly distributed throughout the space. The BGD42P uses a direct vent system, providing safe and efficient venting, which eliminates the need for a traditional chimney and minimizes heat loss.

On the other hand, the BGD42N offers a more traditional appearance, making it an excellent choice for those who prefer classic design elements. Like its counterpart, it boasts a 42-inch viewing area and a high-efficiency burner. However, the BGD42N incorporates a realistic log set, enhancing its traditional appeal while still delivering exceptional heat output and efficiency. Both models are equipped with Napoleon's advanced electronic ignition system, ensuring quick and reliable starts even during power outages.

One of the standout technologies featured in both models is the proprietary PHAZER log set. This innovative design enhances the realism of the flame presentation, resembling a natural wood-burning fire. Additionally, Napoleon’s exclusive heat management system allows users to maximize comfort while minimizing energy consumption.

Both fireplaces come with customizable options, including a variety of decorative media such as river rocks or glass beads, allowing homeowners to personalize their space to match their unique style. Furthermore, Napoleon offers optional remote controls, making operation effortless.

In summary, the BGD42P and BGD42N models from Napoleon Fireplaces exemplify the company’s dedication to delivering high-quality, stylish, and efficient home heating solutions. With a blend of modern technology and classic design elements, these fireplaces not only provide warmth but also enhance the ambiance of any living area. Whether you lean towards contemporary or traditional aesthetics, Napoleon's offerings are sure to meet and exceed expectations, making them a worthwhile investment for any homeowner.