Napoleon Fireplaces EF38H Operation, Remote Control Initialization, Usage Of The Remote Control

Models: EF38H

1 12
Download 12 pages 8.07 Kb
Page 5
Image 5
OPERATION

5

OPERATION

This fireplace is supplied with a infrared remote control. This remote control operates with an arc of 50º and has to be pointed at the infrared eye for it to work. (See fig. 1)

REMOTE CONTROL INITIALIZATION

This procedure is required every time the power is turned off, or lost to the unit.

1.Turn on the power button of the hand held remote con- trol. If there is no beep, access the front control panel.

2.To access the control panel, open the louvres with the louvre tabs.

3.Make sure that the main power switch 1 of the front con- trol panel is turned on.

4.Repeat step #1.

USAGE OF THE REMOTE CONTROL

A - Main power on/off : Activates the power to the firelace from the remote control.

B - Fire Log Accent Light: To illuminate

 

the fireplace.(Can be used as a Nite Lite)

C

C - Flame effect and speed: 1,2,3,4, off.

D

D - Fan/Heater on/off: Turns the fan

 

and heater on and off.

 

E - Sound (optional)

 

Batteries NOT included.

Two AA batteries required.

MANUAL CONTROLS

By opening the top louvres with the louvre tabs you can access the manual controls for the fireplace.

1.Power - activates power to the fireplace. Must be on for the fireplace to work.

2.Manual Control - activates buttons 3, 4 & 5.

3.Fire Log Accent Light - switches the light on and off that illuminates the fireplace. (Can be used as a Nite Lite).

4.Flame Effect and Speed - switches the flame on. Re- peated pressing of the switch cycles the flame through speeds 1 to 4 and off.

5.Fan / Heater - turns the fan and heater on and off.

6.Thermostat - Controls the temperature of the area.

To increase the temperature, turn the dial clockwise.

Note

The heater may emit a slight, harmless odour when first used. This odour is a

Bnormal condition caused by initial heat- ing of internal heater parts. Thereaf-

ter, any odour is normally the result

Eof household dust settling on the heater element.

A

6

5

4

3

2

1

Manual Controls

MAINTENANCE

BULB REPLACEMENT

If you notice the flame look is darker on one side of the fireplace, check the light bulbs to ensure that one has not burned out.

Bulb must be replaced with a MAX 60 watt incandescent clear light bulb.

1.Replace the bulb, turn the circuit breaker off or unplug the appliance.

2.Remove the front facia.

3.Detach the light access panel by removing the four screws.

4.Replace the burned out light bulb using a new 60 watt clear incandescent bulb.

5.Replace access panel and front facia.

6.Turn on the power or plug the appliance back in.

7.Turn on the main power and test.

FIGURE 1

Infrared Eye

Light Access Panel

W415-0330 / B / 03.25.04

Page 5
Image 5