Napoleon Fireplaces EPA 1100C, EPA 1100L, EPA 1400, EPI 1401, EPI 1101 Fan Service Or Replacement

Models: EPI 1101 EPA 1100 EPA 1100C EPI 1401 EPA 1400 EPA 1900 EPA 1400L EPA 1100L

1 16
Download 16 pages 27.59 Kb
Page 9
Image 9
1101 FAN SERVICE OR REPLACEMENT
GASKET
THERMAL SWITCH
FIGURE 13

1101 FAN SERVICE OR REPLACEMENT

1.Turn off all electrical power to the insert. Remove the glass door and set aside in a safe place.

2. Remove the top right side bricks from inside the firebox, 4-#7's and 2- #2's. Then remove the rest of the side and back bricks from the right side of the 1101 insert. It is not necessary to remove the bottom bricks.

9

1401 FAN SERVICE OR REPLACEMENT

1.Turn off all electrical power to the insert. Remove the glass door and set aside in a safe place.

2.Remove the two screws from the outer edge of the side panel(s).

3.Push the side panel toward the door and pull away from the insert, releasing the panel from the keyed slot.

4.Service or replace the fan(s) as required.

5.Re-install the side panel(s) by reversing the proce- dure.

3. The access panel can be removed by taking out the 8 #10 self taping

HEAT

G B

screws. A 5/16" nut driver will be required to com- plete this job. Unplug wires from the thermal switch on the panel. See

FIGURE 13.

4.Remove the securing wingnut from the fan mounting bracket, slide the bracket to the right and rotate the left side of the assembly out of the cavity to clear the blower motor. Disconnect the two wires from the fan motor. Re- move the ground wire from the fan mounting bracket, then the assembly can be taken out of the rear cavity through the access door opening.

5.Remove the 3 screws that hold the fan to the mount- ing bracket. Service or replace the fan as required.

 

GROUND STUD

SECURING

 

 

 

 

 

 

WINGNUT

TAB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FIGURE 14

6. Reinstall the blower assembly WIRES making sure the blower bracket is seated under the securing tab.

FIGURE 14. Reattach the wire con- nectors. FIGURE 15.

7.Replace the gasket on the ac- cess door. To replace the access panel, reverse Step 3 .

8.Replace the bricks into the fire- box. Reinstall the door.

SENSOR

W

FIGURE 16

FIGURE 15

W415-0360 / 11.05.02

Page 9
Image 9
Napoleon Fireplaces EPA 1100C, EPA 1100L, EPI 1401, EPI 1101, EPA 1400L, EPA 1900 specifications Fan Service Or Replacement