STOVE INSTALLATION
FIGURE 2A

5

STOVE INSTALLATION

INSTALLING THE LEGS

To avoid being damaged during shipping, the stove has been bolted to the pallet and must be unbolted before the stove can be installed.

1.Remove the 4 nuts and washers from the underside of the pallet.

2.Lift the stove up and away from the pallet to clear the

threaded studs sticking through the pallet. Place the stove on its back onto a pro- tective surface such as a car- pet or blanket to avoid scratches during leg installa- tion.

STOVE INSTALLATION

If the stove is to be installed on a

 

 

 

 

 

combustible floor, it must be placed

 

 

 

 

 

on an approved non-combustible

 

 

 

 

 

hearth pad, that extends 8" (200mm)

 

 

 

 

 

beyond the stove sides and back,

 

 

 

 

 

and 18" (455mm) to the front. It must

 

 

 

 

 

be installed with a minimum height

 

 

 

 

 

of 7’ between the stove base and

 

 

 

 

 

the ceiling.

FIGURE 4A

BACK WALL

 

 

 

 

BACK WALL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

 

 

45°

 

 

WALLSIDE

 

 

 

WALLSIDE

 

 

 

 

 

 

 

 

 

A

 

C

 

 

 

 

 

 

 

 

 

 

FIGURE 4B

SINGLE WALL CHIMNEY CONNECTOR*

 

 

1100/1100L/1150

1400/1400L

1900

 

A

12” (305 mm)

12” (305 mm)

22” (560 mm)

 

B

10” (254 mm)

12” (305 mm)

12” (305 mm)

 

C

6” (152 mm)

6” (152 mm)

8” (205 mm)

 

* CLEARANCES CAN BE REDUCED WITH SHIELDING ACCEPTABLE TO LOCAL

 

AUTHORITIES. REDUCED INSTALLATION MUST COMPY WITH NFPA 211 or

 

CAN/CSA-B365.

 

 

 

 

DOUBLE WALL CHIMNEY CONNECTOR

 

 

1100/1100L

1400/1400L

1900

 

A

10”

(254 mm)

10” (254 mm)

22” (560 mm)

 

B

6”

(152 mm)

6” (152 mm)

12” (305 mm)

FIGURE 2B

C

2”

(50 mm)

4” (102 mm)

8” (205 mm)

 

 

 

 

 

3.Remove the four additional nuts from each of the four studs.

4.Use four of the nuts and washers removed above to install the legs as illustrated in FIGURES 2a & 2b.

5.Lift the stove up and gently set down on all four legs. Do not pivot unit up on its legs, as this could result in damage to the legs.

ALCOVE INSTALLATION

Model 1100 only may be installed, using a listed double wall connector, such as Security DL6 in Canada, the Simpson Duravent Plus DVL in the USA or an equivalent double wall connector, into an alcove having a depth of no more than 4 feet and a height of at least 7 feet. The mini- mum clearances are as shown in FIGURE 3.

9"

 

6"

 

14"

4 FOOT

MAX.

 

23"

ALCOVE

FIGURE 3

NOTE:CLEARANCES ARE UNABLE TO BE REDUCED FOR THE 1150 BY USING DOUBLE WALL PIPE.

CHIMNEY CONNECTION

A 6” diameter single wall stove pipe, used to connect the stove to the chimney, must be installed with the crimped end toward the stove. This will ensure that the moisture which condenses from the burning wood will flow back into the fire chamber. Each joint in the stove pipe must be se- cured with at least three sheet metal screws.

This room heater must be connected to:

1)A chimney complying with the requirements for Type HT chimneys in the Standard for Chimneys, Factory-Built, Resi- dential Type and Building Heating Appliance UL 103, or

2)A code-approved masonry chimney with a flue liner. Vent the stove into a masonry chimney or an approved, insulated solid-fuel stainless-steel chimney with as short and straight a length of six-inch (150mm) diameter smoke pipe as possible. Connection to a masonry chimney must be by a metal or masonry thimble cemented in place.

An insulated stainless steel chimney must be supported at the ceiling or roof and its installation must comply with its manufacturer's instructions.