14

TROUBLE SHOOTING GUIDE

BEFORE ATTEMPTING TO TROUBLESHOOT, PURGE YOUR UNIT AND INITIALLY LIGHT THE PILOT AND THE MAIN BURNER WITH THE GLASS DOOR REMOVED.

SYMPTOM

 

PROBLEM

 

TEST SOLUTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pilot will not light.

No spark at pilot burner

-

check if pilot can be lit by a match

 

 

 

 

 

-

check that the wire is connected to the push button ignitor.

 

 

 

 

 

-

check if the push button ignitor needs tightening.

 

 

 

 

 

-

replace the push button ignitor.

 

 

 

 

 

 

 

 

 

Spark gap is incorrect

- spark gap should be 0.150" to 0.175" (5/32" to 11/64" approx.)

 

 

 

from the electrode tip and the pilot burner.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No gas at the pilot burner

-

check that the manual valve is turned on.

 

 

 

 

 

-

check the pilot orifice for blockage.

 

 

 

 

 

-

replace the valve.

 

 

 

 

 

-

call the gas distributor.

 

 

 

 

 

 

 

 

 

Out of propane gas.

-

fill the tank.

 

 

Pilot goes out when the gas knob is re- leased.

 

System is not correctly purged.

- purge the gas line with the glass door open.

 

 

 

 

 

 

Out of propane gas

-

fill the tank.

 

 

 

 

Pilot flame is not large enough

-

turn up the pilot flame.

Pilot flame is not engulfing the

-

turn up pilot flame.

thermocouple.

-

replace pilot assembly.

 

 

 

 

 

 

Thermocouple shorting.

-

loosen and tighten thermocouple.

 

 

-

clean thermocouple and valve connection.

 

 

-

replace thermocouple.

 

 

-

replace valve.

 

Faultly thermocouple.

-

replace.

 

Faulty valve.

-

replace.

Pilot burning; no gas

 

 

Main burner orifice is plugged.

-

remove stoppage in orifice.

to main burner; gas

 

 

 

 

 

 

 

Faulty thermopile.

-

replace.

knob is on 'HI'; wall

 

 

 

Faulty themostat or switch.

-

connect a jumper wire across the wall switch terminals; if

switch / thermostat is

 

 

 

 

 

on.

main burner lights, replace thermostat.

 

-disconnect the switch wires & connect a jumper wire across terminals 1 & 3; if the main burner lights, check the wires for defects and / or replace wires.

Faulty valve.

-

replace.

 

 

 

Pilot goes out while Gas piping is undersized.

-

turn on all gas appliances and see if pilot flame flutters,

standing; Main burner

diminishes or extinguishes, especially when main burner ig-

is in 'OFF' position.

nites. Monitor supply pressure.

 

-

check if supply piping size is to code. Correct all undersized

 

piping.

 

 

 

Main burner goes out; pilot stays on.

Pilot flame is not large enough -

turn up pilot flame.

or not engulfing the thermopile. - replace pilot assembly.

 

 

 

Thermopile shorting

-

clean thermopile and thermopile connection to valve.

Remote wall switch wire is too - shorten wire to correct length or wire gauge. long, too much resistance in

the system

Faulty thermostat or switch

- replace

W415-0223 / D / 01.12.04

Page 14
Image 14
Napoleon Fireplaces GDIZC-P, GDIZC-N manual Trouble Shooting Guide, Symptom Problem Test Solution

GDIZC-P, GDIZC-N specifications

Napoleon Fireplaces has long been recognized as a leader in the fireplace industry, and the GDIZC-N and GDIZC-P models are prime examples of their commitment to innovation and quality. These modern, two-sided gas fireplaces are designed to offer both aesthetic appeal and functional efficiency, making them ideal for a wide range of residential settings.

The GDIZC-N (natural gas) and GDIZC-P (propane) are contemporary gas fireplaces that can be installed in a variety of configurations, including as a room divider or as a standalone feature in a living room or dining area. Their unique design allows for maximum viewing from two sides, creating a stunning focal point that enhances the ambiance of any space. The clean lines and sleek design fit seamlessly into modern architecture while providing warmth and comfort.

One of the standout features of the GDIZC models is their superior heating capabilities. With an impressive heat output of up to 30,000 BTUs, these fireplaces ensure that your home remains cozy during the coldest months. They are equipped with high-efficiency heat exchangers that maximize warmth while minimizing heat loss. This efficiency not only contributes to comfort but also helps in reducing energy costs, making them an economically sound choice for homeowners.

Another notable characteristic of the GDIZC-N and GDIZC-P is the radiant heat technology. This system uses direct heat to warm objects and people in the room, creating an inviting atmosphere. Additionally, the fireplaces are designed with an electronic ignition system, allowing for easy start-up and consistent operation. The inclusion of a built-in safety shut-off feature ensures peace of mind when using these efficient heating units.

Moreover, Napoleon has incorporated contemporary styling options, including customizable media trays and a range of decorative media choices like glass beads and driftwood logs. The advanced LED lighting enhances the realistic flame effect and allows for customizable ambiance, giving users the ability to set the perfect mood for any occasion.

The GDIZC-N and GDIZC-P models are also designed with ease of installation in mind. They come with a versatile venting system, allowing for various venting options to accommodate different home layouts. This flexibility makes it easier for homeowners to integrate these stunning fireplaces into their existing spaces without significant renovations.

In summary, the Napoleon Fireplaces GDIZC-N and GDIZC-P models stand out for their impressive heating capabilities, elegant design, and technological features. With their two-sided viewing, advanced efficiency, and extensive customization options, these fireplaces are a perfect combination of functionality and style for modern living environments. Whether enhancing a cozy living space or serving as a striking room divider, these fireplaces deliver warmth and beauty that any home can benefit from.