ZERO CLEARANCE INSULATING LINER

ZERO CLEARANCE INSULATING LINER

INSTRUCTION GUIDE

This liner is designed for use in a combustible enclosure; the liner must be supported from the bottom by a ledge on either side or a full deck beneath the liner (refer to opening diagram). Please use this manual in conjunction with your main manual to properly assemble your built in grill.

KIT CONTENTS

BOTTOM PANEL

1PC

 

 

SIDE PANELS

2PCS

 

 

REAR PANEL

1PC

W

 

#8 x ½” TEK SCREWS

15PCS

 

 

 

#14 x ½” HEX HEAD SCREWS

6PCS

 

 

 

 

2”MIN

6.500”

 

 

2.000”

H

Model

 

Dimensions

 

 

 

 

 

 

 

 

W

 

D

 

H

 

 

 

 

 

 

BIZC450

35.875”

 

22.937”

 

11.125”

 

 

 

 

 

 

BIZC600

44.125”

 

22.937”

 

11.125”

 

 

 

 

 

 

D

GAS

INLET

OPENING

34” RECOMMENDED

The installation must be performed by a licensed gas fitter, and all connections must be leak tested before operating the grill.

BUILT IN PROPANE GAS HOOK-UP: The piping up to the gas grill is the responsibility of the installer and piping should be located as shown in the built-in instructions. Do not use hose to connect the unit. It must be connected with either rigid pipe, copper tube or an approved flexible metal connector. The installation must comply with CAN B149.1 Natural Gas and Propane installation code in Canada, or to the National Fuel Gas code, ANSI Z223.1 in the United States. The minimum recommended piping size is NPS 1/2" for rigid pipe, and 1/2" OD for copper tubing (based on a 20 ft run). Longer runs may require larger sizes to conform with CAN B149.1. Propane Gas Installation Code in Canada or to the National Fuel Gas Code, ANSI Z223.1 in the United States. The gas supply must be connected to the 3/8” flare elbow fitting located under the right hand side of the control panel. If installing a side burner, a separate line must be branched off to the side burner unit and enter the side burner opening at the specified location. If the enclosure is to house a propane cylinder, the tank portion of the enclosure must be ventilated according to local codes, and must not have communication with the cavity used to enclose the gas grill. The tank can not be stored below the gas grill.

BUILT IN NATURAL GAS HOOK-UP: The piping up to the gas grill is the responsibility of the installer and piping should be located as shown in the built-in instructions. Do not use hose to connect the unit. It must be connected with either rigid pipe, copper tube or an approved flexible metal connector. The installation must comply with CAN B149.1 Natural Gas and Propane Installation Code in Canada, or to the National Fuel Gas Code, ANSI Z223.1 in the United States. The minimum recommended piping size is NPS 1/2" for rigid pipe, and 5/8" OD for copper tubing (based on a 20 ft run). Longer runs may require larger sizes to conform with CAN B149.1. Natural Gas Installation Code in Canada or to the National Fuel Gas Code, ANSI Z223.1 in the United States.

Built in units are supplied with a drip pan which holds only a minimal amount of grease. To prevent grease fires, the pan must be cleaned after each use.