Sanyo CM3212, KMS1812 service manual Cooling Capacity, 230V CM3622 / KMS0712⋅1

Models: KMS1812 CM3212 KMS0712

1 22
Download 22 pages 63.65 Kb
Page 12
Image 12
4. COOLING CAPACITY

4. COOLING CAPACITY

230V

CM3622 / KMS07121

Rating Capacity: 7,000 BTU/H

 

 

Air Flow Rate: 220 CFM

 

Evaporator

 

 

 

Condenser

 

 

 

 

 

 

 

 

 

 

Ent. Temp.

°F/(°C)

 

 

Ambient Temp.

°F/(°C)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WB

 

DB

 

75

 

85

 

95

 

105

115

 

 

(23.9)

 

(29.4)

(35.0)

 

(40.6)

(46.1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TC

6,930

 

6,620

 

6,300

 

5,940

5,460

 

 

 

kW

0.48

 

0.52

 

0.57

 

0.61

0.67

59

 

72 (22.2)

SHC

5,290

 

5,130

 

4,980

 

4,810

4,590

(15.0)

 

76 (24.4)

SHC

6,030

 

5,880

 

5,730

 

5,560

5,330

 

 

80 (26.7)

SHC

6,810

 

6,620

 

6,300

 

5,940

5,460

 

 

84 (28.9)

SHC

6,930

 

6,620

 

6,300

 

5,940

5,460

 

 

88 (31.1)

SHC

6,930

 

6,620

 

6,300

 

5,940

5,460

 

 

 

TC

7,170

 

6,940

 

6,670

 

6,310

5,810

 

 

 

kW

0.48

 

0.53

 

0.57

 

0.62

0.69

63

 

72 (22.2)

SHC

4,390

 

4,290

 

4,170

 

4,010

3,800

(17.2)

 

76 (24.4)

SHC

5,130

 

5,030

 

4,910

 

4,750

4,540

 

 

80 (26.7)

SHC

5,910

 

5,810

 

5,690

 

5,530

5,320

 

 

84 (28.9)

SHC

6,650

 

6,550

 

6,430

 

6,270

5,810

 

 

88 (31.1)

SHC

7,170

 

6,940

 

6,670

 

6,310

5,810

 

 

 

TC

7,360

 

7,250

*7,000

 

6,620

6,610

 

 

 

kW

0.48

 

0.53

 

0.58

 

0.63

0.70

67

 

72 (22.2)

SHC

3,470

 

3,420

 

3,320

 

3,170

2,990

(19.4)

 

76 (24.4)

SHC

4,210

 

4,160

 

4,060

 

3,910

3,730

 

 

80 (26.7)

SHC

4,990

 

4,940

 

4,840

 

4,680

4,510

 

 

84 (28.9)

SHC

5,730

 

5,680

 

5,580

 

5,430

5,250

 

 

88 (31.1)

SHC

6,470

 

6,420

 

6,320

 

6,170

5,990

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TC

7,600

 

7,470

 

7,280

 

6,950

6,550

 

 

 

kW

0.49

 

0.54

 

0.59

 

0.65

0.72

71

 

72 (22.2)

SHC

2,520

 

2,470

 

2,400

 

2,280

2,140

(21.7)

 

76 (24.4)

SHC

3,260

 

3,210

 

3,140

 

3,020

2,880

 

 

80 (26.7)

SHC

4,040

 

3,990

 

3,920

 

3,800

3,660

 

 

84 (28.9)

SHC

4,780

 

4,730

 

4,660

 

4,540

4,400

 

 

88 (31.1)

SHC

5,520

 

5,480

 

5,410

 

5,290

5,140

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TC

7,740

 

7,660

 

7,490

 

7,220

6,930

 

 

 

kW

0.50

 

0.55

 

0.60

 

0.66

0.73

75

 

76 (24.4)

SHC

2,320

 

2,290

 

2,240

 

2,150

2,050

(23.9)

 

80 (26.7)

SHC

3,100

 

3,070

 

3,010

 

2,920

2,830

 

 

84 (28.9)

SHC

3,840

 

3,810

 

3,750

 

3,670

3,570

 

 

88 (31.1)

SHC

4,580

 

4,550

 

4,500

 

4,410

4,310

 

 

 

 

 

 

 

 

 

 

 

 

TC: Total Cooling Capacity (BTU/H)

SHC: Sensible Heat Capacity (BTU/H)

kW: Compressor Input (kW)

Remarks: Rating conditions (* mark) are: Outside ambient temperature 95°F DB

Indoor unit entering air temperature 80°F DB/67°F WB

7WM – 700699

Page 12
Image 12
Sanyo CM3212, KMS1812 service manual Cooling Capacity, 230V CM3622 / KMS0712⋅1