Sanyo service manual CM3212 / KMS0712+KMS1812, CM3212 / KMS7012⋅2+KMS1812

Models: KMS1812 CM3212 KMS0712

1 22
Download 22 pages 63.65 Kb
Page 18
Image 18
CM3212 / KMS0712+KMS1812

CM3212 / KMS0712+KMS1812

Performance at

Indoor Units

 

Outdoor Unit

Complete Unit

230/208V – 1ø – 60Hz

Fan Motor

Compressor

 

 

 

 

 

 

 

 

 

 

 

 

 

Rating Conditions

A

0.55

/ 0.54

1.45

/ 1.42

9.80 / 10.64

11.8

/ 12.6

 

 

 

 

 

 

 

 

W

124

/ 108

330

/ 290

2,246 / 2,202

2,700

/ 2,600

 

 

 

 

 

 

 

 

 

Locked-Rotor Amperes

A

0.19 + 0.45

/ 0.18 + 0.40

1.95

/ 1.77

22 + 54

 

 

 

 

 

 

 

 

 

Remarks: Rating conditions are: Outside air temperature 95°F DB/75°F WB

Indoor unit entering air temperature 80°F DB/67°F WB

CM3212 / KMS70122+KMS1812

Performance at

Indoor Units

 

Outdoor Unit

Complete Unit

230/208V – 1ø – 60Hz

Fan Motor

Compressor

 

 

 

 

 

 

 

 

 

 

 

 

 

Rating Conditions

A

0.70

/ 0.68

1.45

/ 1.42

12.85 / 13.90

15.0

/ 16.0

 

 

 

 

 

 

 

 

W

158

/ 136

330

/ 290

2,912 / 2,874

3,400

/ 3,300

 

 

 

 

 

 

 

 

 

Locked-Rotor Amperes

A

0.19 + 0.19 + 0.45

/ 0.18 + 0.18 + 0.40

1.95

/ 1.77

22 + 22 + 54

 

 

 

 

 

 

 

 

 

Remarks: Rating conditions are: Outside air temperature 95°F DB/75°F WB

Indoor unit entering air temperature 80°F DB/67°F WB

13WM – 700699

Page 18
Image 18
Sanyo service manual CM3212 / KMS0712+KMS1812, CM3212 / KMS7012⋅2+KMS1812