LEAK TESTING INSTRUCTIONS

DO NOT USE A FLAME TO LEAK TEST.

LEAK TESTING: This must be done before initial use, annually and whenever any gas components are replaced or serviced. No smoking while performing this test, and remove all sources of ignition. See Leak Testing Diagram for areas to check.

1.Turn all burner controls to off. Turn supply valve on.

2.Brush a half and half solution of liquid soap and water onto all joints and connections of the regulator, hose, manifolds and valves.

3.Bubbles will indicate a gas leak. Either tighten the loose joint or replace the part with one recommended by the dealer.

4.If the leak cannot be stopped, shut off the gas supply, disconnect it and have the barbecue inspected by your gas supplier or dealer. Do not use the appliance until the leak has been corrected.

5.Turn off gas supply.

A LEAK TEST MUST BE PERFORMED AT THE FOLLOWING TIMES:

•BEFORE INITIAL USE EVEN IF THE GRILL WAS DEALER ASSEMBLED.

•AT LEAST ONCE PER YEAR.

•WHENEVER ANY GAS COMPONENT HAS BEEN REPLACED.

23

Page 23
Image 23
Napoleon Grills MIRAGE 485 operating instructions Leak Testing Instructions, Do not USE a Flame to Leak Test