© National Instruments Corp. 11 FP-RLY-420
Maximum switching frequency
Mechanical................................. 20 operations per second
Electrical.....................................1 operation per second at
maximum load
Relays operate time...........................6 ms typical, 8 ms max.
Relays release time........................... 3 ms typical, 4 ms max.
Relay bounce time............................ 3 ms max.
Contact material................................Gold-plated silver cadmium
oxide
Isolation (CH–GND and CH–CH)....3,000 Vrms
Safety isolation, working voltage
(CH–GND only)............................... 250 Vrms, designed per IEC
1010 as double insulated
PhysicalIndicators..................................... .....Green POWER and
READY indicators, 8 green
output state indicators
Weight...............................................160 g (5.6 oz.)
Power RequirementsPower from network module............ 1700 mW
EnvironmentOperating temperature...................... –40 to +70 °C
Storage temperature..........................– 55 to +100 °C
Relative humidity..............................5% to 90% noncondensing
CE Mark ComplianceThis product meets applicable EU directive(s) as follows:
Safety isolation................................. EN 61010 (double insulation
for 250 Vrms working
isolation, installation
category II)
EMC Directive
Immunity....................................EN 50082-1:1994
Emissions................................... EN 55011:1991 Group I
Class A at 10 m