wibic–Windows Interface Bus Interactive Control Utility Chapter 5
NI-488.2 User Manual for Windows 5-6 © National Instruments Corp.
Table 5-1. Syntax for Device-Level NI-488 Functions in wibic
Syntax Description
ibask mn Return configuration information where mn is a mnemonic for a
configuration parameter or equivalent integer value
ibbna brdname Change access board of device where brdname is symbolic
name of new board
ibclr Clear specified device
ibconfig mn v Alter configurable parameters where mn is mnemonic for a
configuration parameter or equivalent integer value
ibdev v v v v v vOpen an unused device
ibdev parameters are board id, pad , sad , tmo , eos , eot
ibeos v Change/disable EOS message
ibeot v Enable/disable END message
ibln v v Check for presence of device on the GPIB at pad, sad
ibloc Go to local
ibonl v Place device online or offline
ibpad v Change primary address
ibpct Pass control
ibppc v Parallel poll configure
ibrd v Read data where v is the bytes to read
ibrda v Read data asynchronously where v is the bytes to read
ibrdf flname Read data to file where flname is pathname of file to read
ibrpp Conduct a parallel poll
ibrsp Return serial poll byte
ibsad v Change secondary address
ibstop Abort asynchronous operation
ibtmo v Change/disable time limit
ibtrg Trigger selected device
ibwait mask Wait for selected event where mask is a hex, octal, or decimal
integer or a mask bit mnemonic
ibwrt string Write data
ibwrta string Write data asynchronously
ibwrtf flname Write data from a file where flname is pathname of file to write