Appendix D Hardware Specifications
NI-DNET User Manual D-2 ni.com
Storage environment
Ambient temperature.......................–20 to 70 °C
Relative humidity............................5 to 90%, noncondensing
PXI-CAN SeriesDimensions.............................................16.0 by 10.0 cm
(6.3 by 3.9 in.)
Power requirement..................................+5 VDC, 775 mA typical
I/O connector..........................................9-pin D-SUB for each port
(standard)
or
5-pin Combicon-style pluggable
DeviceNet screw terminal
(high-speed CAN only)
Operating environment
Ambient temperature.......................0 to 55 °C
Relative humidity............................10 to 90%, noncondensing
Storage environment
Ambient temperature.......................–20 to 70 °C
Relative humidity............................5 to 95%, noncondensing
(Tested in accordance with IEC-60068-2-1, IEC-60068-2-2,
IEC-60068-2-56.)
Functional Shock....................................30 g peak, half-sine, 11ms pulse
(Tested in accordance with IEC-60068-2-27. Test profile developed in
accordance with MIL-T-28800E.)
Random Vibration
Operating.........................................5 to 500 Hz, 0.3 grms
Nonoperating...................................5 to 500 Hz, 2.4 grms
(Tested in accordance with IEC-60068-2-64. Nonoperating test profile
developed in accordance with MIL-T-28800E and MIL-STD-810E
Method 514.)