NI 9852 Operating Instructions 16 ni.com
SpecificationsThe following specifications are typical for the range –40 to 70 °C
unless otherwise noted.
Low-Speed/Fault-Tolerant CAN Characteristics
Transceiver........................................Philips TJA1054A
Max baud rate................................... 125 Kbps
CAN_H, CAN_L bus lines
voltage...............................................–27 to +40 VDC
Supply voltage range (VSUP0/VSUP1)
CAN0............... ..........................+8 to +36 VDC
CAN1............... ..........................+8 to +36 VDC
RRTH............................................1 .11 kΩ ± 0.5% or
4.99 kΩ ± 0.5%
RRTL............................................ 1.11 kΩ ± 0.5% or
4.99 kΩ ± 0.5%
MTBF............................................... 1,052,836 hours at 25 °C;
Bellcore Issue 6, Method 1,
Case 3, Limited Part Stress
Method