Chapter 3 LEDs, DIP Switches, and Connectors
© National Instruments Corporation 3-13 NI CVS-1450 Series User Manual
Figure 3-8. 44-Pin DSUB Connector
Table3-5 lists pin numbers, signal names, and signal descriptions for the 44-pin connector on the CVS-1450 device and the 37-pin terminal block.
Caution Do not draw more than 500mA combined from the Viso pins on the 44-pin
DSUB connector. Do not draw more than 100mA from 24 V or 30 V isolated outputs. Do not draw more than 50mA from 5 V isolated outputs.
Table 3-5. 44-Pin DSUB and 37-Pin Terminal Block Connector Signals
44-Pin
DSUB on
CVS-1450
Device
Pin Number
37-Pin
Term in al
Block
Pin Number Signal Name Primary Function Alternate Function
1 1 TTL Input 0 Pulse generator trigger input General-purpose input
2 3 C Common-mode signal of the
CVS-1450 device main
power
3 4 TTL Output 0 Watchdog timer output General-purpose output
4 5 TTL Output 1 Pulse generator output Gen eral-purpose output