Appendix A Specifications
NI ExpressCard MXI Series User Manual A-4 ni.com
Environment1
Maximum altitude...................................2,000 m (800 mbars)
(at 25 °C ambient temperature)
Pollution Degree.....................................2
Indoor use only
Operating Environment
Ambient temperature range....................0 to 55 °C
(Tested in accordance with
IEC-60068-2-1 and
IEC-60068-2-2. Meets
MIL-PRF-28800F Class 3 low
temperature limit and
MIL-PRF-28800F Class 2 high
temperature limit.)
Relative humidity range..........................10 to 90%, noncondensing
(Testedin accordance with
IEC-60068-2-56.)
Storage Environment
Ambient temperature range....................– 40 to 71 °C
(Tested in accordance with
IEC-60068-2-1 and
IEC-60068-2-2. Meets
MIL-PRF-28800F Class 3 limits.)
Relative humidity range..........................5 to 95%, noncondensing
(Testedin accordance with
IEC-60068-2-56.)
Shock and Vibration
Operational shock...................................30 g peak, half-sine, 11 ms pulse
(Tested in accordance with
IEC-60068-2-27. Meets
MIL-PRF-28800F Class 2 limits.)
1 Specifications are subject to change without notice.