Appendix A Specifications
NI ExpressCard MXI Series User Manual A-6 ni.com
Operating Environment
Module ambient temperature range........0 to 65 °C
(Tested in accordance with
IEC-60068-2-1 and
IEC-60068-2-2.)
Operating relative humidity....................5 to 95%, noncondensing
(Testedin accordance with
IEC-60068-2-56.)
Storage Environment
Ambient temperature range....................–20 to 65 °C
(Tested in accordance with
IEC-60068-2-1 and
IEC-60068-2-2.)
Nonoperating thermal shock...................–20 to 65 °C, 5 shocks
Shock and Vibration
Nonoperating shock................................50 g, 11 ms
(Tested in accordance with IEC
60068-2-27.)
Nonoperating vibration,
sinusoidal................................................15 g 100 to 2000 Hz
(Tested in accordance with IEC
60068-2-6.)
Nonoperating drop test...........................2 drops in 3 mutually exclusive
axes from 75 cm onto
no-cushioning vinyl tile surface
Cleaning
If you need to clean the module, use a soft, nonmetallic brush. Make sure
that the module is completely dry and free from contaminants before
returning it to service.