Appendix A Specifications
© National Instruments Corporation A-3 NI PXIe-8105 User Manual
Operating EnvironmentNI PXIe-8105
Ambient temperature range ............5 to 50 °C (Tested in accordance
with IEC-60068-2-1 and
IEC-60068-2-2. Meets
MIL-PRF-28800F Class 3
high temperature limit.)
NI PXIe-8105
Extended Temperature Option
Ambient temperature range ............0 to 55 °C (Tested in accordance
with IEC-60068-2-1 and
IEC-60068-2-2. Meets
MIL-PRF-28800F Class 3
low temperature limit and
MIL-PRF-28800F Class 2
high temperature limit.)
Relative humidity range......................... 10% to 90%, noncondensing
(Tested in accordance with
IEC-60068-2-56.)
Caution The operating temperature must not be exceeded, even when used in a chassis
with a higher temperature range.
Storage EnvironmentNI PXIe-8105
Ambient temperature range ............– 40 to 65 °C (Tested in
accordance with IEC-60068-2-1
and IEC-60068-2-2. Meets
MIL-PRF-28800F Class 3
low temperature limit.)
NI PXIe-8105
Extended Temperature Option
Ambient temperature range ............– 40 to 71 °C (Tested in
accordance with IEC-60068-2-1
and IEC-60068-2-2. Meets
MIL-PRF-28800F Class 3 limits.)
Relative humidity range......................... 5% to 95% noncondensing
(Tested in accordance with
IEC-60068-2-56.)