Appendix A Specifications
NI PXIe-8105 User Manual A-4 ni.com
Shock and VibrationOperational shock...................................30 g peak, half-sine, 11 ms pulse
(Tested in accordance with
IEC-60068-2-27. Meets
MIL-PRF-28800F Class 2 limits.)
Random vibration
Operating.........................................5 to 500 Hz, 0.3 grms
(with solid-state hard drive)
Nonoperating...................................5 to 500 Hz, 2.4 grms
(Tested in accordance with
IEC-60068-2-64. Nonoperating
test profile exceeds the
requirements of
MIL-PRF-28800F, Class 3.)
Note Specifications are subject to change without notice.
SafetyThis product is designed to meet the requirements of the following
standards of safety for electrical equipment for measurement, control, and
laboratory use:
• EN 61010-1, IEC 61010-1
• UL 61010-1, CAN/CSA-C22.2 No. 61010-1
Note For UL and other safety certifications, refer to the product label, or visit
ni.com./certification, search by model number or product line, and click the
appropriate link in the Certification column.
Electromagnetic CompatibilityThis product is designed to meet the requirements of the following
standards of EMC for electrical equipment for measurement, control,
and laboratory use:
• EN 61326 EMC requirements; Minimum Immunity
• EN 55011 Emissions; Group 1, Class A
• CE, C-Tick, ICES, and FCC Part 15 Emissions; Class A
Note For EMC compliance, operate this device according to printed documentation.