Theory of Operation
The voltage divider splits the input voltage (Vin) between two resistors
(R1and R2), causing the voltage on each resistor to be noticeably lower than
Vin. Use Equation 5-12 to determine the Vm that the DAQ device measures:
(5-12)
Use Equation 5-13 to determine the overall gain of a voltage divider circuit:
(5-13)
The accuracy of Equation5-13 dep ends on the tolerances of the resistors
that you use.
Caution The SCB-68 is not designed for any input voltages greater than 42V, even if a
user-installed voltage divider reduces the voltage to within the input range of the DAQ
device. Input voltages greater than 42V can damage the SCB-68, any devices connected
to it, and the host computer. Overvoltage can also cause an electric shock hazard for the
operator. NI is not responsible for damage or injury resulting from such misuse.
R2
Vin Vm
+
–
+
–
R1
VmVin
R2
R1R2
+
------------------
=
GVm
Vin
------- R2
R1R2
+
------------------==