SCC-TC Series Thermocouple Input Modules User Guide 16 ni.com
PhysicalTC01 dimensions....................................7.8 cm by 2.92 cm by 1.85 cm
(3.1 in. by 1.15 in. by 0.73 in.)
TC02 dimensions....................................8.89 cm by 2.92 cm by 1.85 cm
(3.50 in. by 1.15 in. by 0.73 in.)
I/O...........................................................One 20-pin right angle male
connector, 3-pin screw terminal
system (SCC-TC02);
two-prong mini-connector
(SCC-TC01)
Screw terminal field-wiring
gauge (SCC-TC02).................................28 to 16 AWG
Maximum Working VoltageMaximum working voltage refers to the signal voltage plus the
common-mode voltage.
Each input must remain within ±12 V of chassis ground.
Installation Category I
EnvironmentalOperating temperature............................0 to 50 °C
Storage temperature................................–20 to 70 °C
Humidity.................................................10 to 90% RH, noncondensing
Maximum altitude...................................2,000 m
Pollution Degree (indoor use only) ........2
SafetyThe SCC-TC0X meets the requirements of the following standards
forsafety and electrical equipment for measurement, control, and
laboratory use:
• IEC 61010-1, EN 61010-1
• UL 3111-1, UL 61010B-1
• CAN/CSA C22.2 No. 1010.1