Appendix A Specifications
Getting Started with Your VXIpc-850 A-2 © National Instruments Corporation
Environmental
Characteristic Specification
Temperature 0° to 55° C Operating;
-20° to 70° C Storage
Relative Humidity 0% to 95% Noncondensing, Operating;
0% to 95% Noncondensing, Storage
EMI FCC Class A Verified, EC Verified
Vibration Operational: 5 to 500 Hz, 0.31 g, 3 axes
Non-operational: 5 to 500 Hz, 2.5 g, 3 axes
Functional Shock MIL-T-28800E Class 3 (per Section 4.5.5.4.1)
Half-Sine Shock Pulse (11 ms duration, 30 g peak,
3 shocks per face)
Note: Random vibration profiles were developed in accordance with
MIL-T-28800E and MIL-STD-810E Method 514. Test levels exceed those
recommended in MIL-STD-810E for Category 1 (Basic Transportation,
Figures 514.4-1 through 514.4-3). Test report available upon request.
Requirements
Characteristic Specification
VXIbus Configuration Space 64 B
A24 or A32 Space 16 KB Minimum (Programmable)
Performance
VME Transfer Rate
Peak D32 33 MB/s
Sustained D32 Reads 13.76 MB/s
Writes 11.37 MB/s