44
10. COLOR Gain Data
Function
The external control equipment changes the COLOR gain data of the plasma
monitor.
Transmission Data
DFH 80H 60H 7FH 03H
DATA00 DATA01DATA02
CKS
DATA00: USER PICTURE Gain Flag 01H
DATA01: COLOR Gain Flag 04H
DATA02: COLOR Gain E0H: -32
*COLOR Gain is from -22 (EAH) to
+22 (16H) only during video. FFH: -01
00H: 0
01H: +01
20H: +32
ACK
7FH 60H 80H 7FH 02H
DATA00 DATA01
CKS
DATA00: USER PICTURE Gain Flag 01H
DATA01: COLOR Gain Flag 04H
11.TINT Gain Data
Function
The external control equipment changes the TINT gain data of the plasma
monitor.
Transmission Data
DFH 80H 60H 7FH 03H
DATA00 DATA01DATA02
CKS
DATA00: USER PICTURE Gain Flag 01H
DATA01: TINT Gain Flag 05H
DATA02: TINT Gain E0H: -32
*TINT Gain is from -22 (EAH) to
+22 (16H) only during video. FFH: -01
00H: 0
01H: +01
20H: +32
ACK
7FH 60H 80H 7FH 02H
DATA00 DATA01CKS
DATA00: USER PICTURE Gain Flag 01H
DATA01: TINT Gain Flag 05H
12. PICTURE MODE Select
Function
The external control equipment sets the picture mode of the plasma monitor.
Transmission Data
DFH 80H 60H 0AH 01H
DATA00
CKS
DATA00: 01H: MEMORY
02H: THEATER
03H: NORMAL
04H: RESET
ACK
7FH 60H 80H 0AH 01H
DATA00
CKS
DATA00: 01H: MEMORY
02H: THEATER
03H: NORMAL
04H: RESET
13. COLOR TEMP SELECT
Function
The external control equipment changes the COLOR TEMP of the plasma
monitor.
Transmission Data
DFH 80H 60H 00H 01H
DATA00
CKS
DATA00: 00H: 1
01H: 2
02H: 3
03H: PRO
ACK
7FH 60H 80H 00H 01H
DATA00
CKS
DATA00: 00H: 1
01H: 2
02H: 3
03H: PRO
NOTE: Set so that at the selection of 1, 2, or 3 of COLOR TEMP
change of the following R/G/B GAIN data cannot be accepted.
14. RED Gain Data
Function
The external control equipment changes the RED Gain Data of the plasma
monitor. Note that this command can be accepted only when PRO is selected
from COLOR TEMP.
Transmission Data
DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS
DATA00: USER PICTURE Gain Flag 01H
DATA01: RED Gain Flag 01H
DATA02: RED Gain 1 (Bias) D8H: -40
FFH: -1
00H: 0
IEH: +30
DATA03: RED Gain 2 (Drive) D8H: -40
FFH: -1
00H: 0
IEH: +30
ACK
7FH 60H 80H 7FH 02H
DATA00 DATA01
CKS
DATA00: USER PICTURE Gain Flag 01H
DATA01: RED Gain Flag 01H