45
15. GREEN Gain DataFunction
The external control equipment changes the GREEN Gain Data of the plasma
monitor. Note that this command can be accepted only when PRO is selected
from COLOR TEMP.
Transmission Data
DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS
DATA00: USER PICTURE Gain Flag 01H
DATA01: GREEN Gain Flag 02H
DATA02: GREEN Gain 1 (Bias) D8H: -40
FFH: -1
00H: 0
IEH: +30
DATA03: GREEN Gain2 (Drive) D8H: -40
FFH: -1
00H: 0
IEH: +30
ACK
7FH 60H 80H 7FH 02H
DATA00 DATA01
CKS
DATA00: USER PICTURE Gain Flag 01H
DATA01: GREEN Gain Flag 02H
16. BLUE Gain DataFunction
The external control equipment changes the BLUE Gain Data of the plasma
monitor. Note that this command can be accepted only when PRO is selected
from COLOR TEMP.
Transmission Data
DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS
DATA00: USER PICTURE Gain Flag 01H
DATA01: BLUE Gain Flag 03H
DATA02: BLUE Gain1(Bias) D8H:-40
FFH:-1
00H: 0
IEH: +30
DATA03: BLUE Gain2(Drive) D8H: -40
FFH:-1
00H: 0
IEH:+30
ACK
7FH 60H 80H 7FH 02H
DATA00 DATA01
CKS
DATA00: USER PICTURE Gain Flag 01H
DATA01: BLUE Gain Flag 03H
17. NR MODE SetFunction
The external control equipment sets the NR (Noise Reduction) mode of the
plasma monitor.
Transmission Data
DFH 80H 60H C0H 01H
DATA00
CKS
DATA00: 01H: NR OFF
02H: NR-1
03H: NR-2
04H: NR-3
ACK
7FH 60H 80H C0H 01H
DATA00
CKS
DATA00: 01H: NR OFF
02H: NR-1
03H: NR-2
04H: NR-3
18. BASS Gain DataFunction
The external control equipment changes the BASS gain data of the plasma
monitor.
Transmission Data
DFH 80H 60H 7FH 03H
DATA00 DATA01DATA02
CKS
DATA00: USER PICTURE Gain Flag 05H
DATA01: BASS Gain Flag 03H
DATA02: BASS Gain F3H: -13
FFH: -01
00H: 0
01H: +01
0DH: +13
ACK
7FH 60H 80H 7FH 02H
DATA00 DATA01
CKS
DATA00: USER PICTURE Gain Flag 05H
DATA01: BASS Gain Flag 03H
19. TREBLE Gain DataFunction
The external control equipment changes the TREBLE gain data of the plasma
monitor.
Transmission Data
DFH 80H 60H 7FH 03H
DATA00 DATA01DATA02
CKS
DATA00: USER PICTURE Gain Flag 05H
DATA01: TREBLE Gain Flag 04H
DATA02: TREBLE Gain F3H: -13
FFH: -01
00H: 0
01H: +01
0DH: +13
ACK
7FH 60H 80H 7FH 02H
DATA00 DATA01
CKS
DATA00: USER PICTURE Gain Flag 05H
DATA01: TREBLE Gain Flag 04H