MINIMUM CLEARANCES:

MINIMUM CLEARANCES:

The Model 91 Bay Fireplace Insert is intended for installation in accordance with the standard for chimneys, fireplaces, vents, and solid-fuel burning appliances. NFPA-211Code: NOTE-This model is not intended for installation into Zero Clearance or pre-fabricated fireplace.

1.The hearth must be of masonry construction and must extend a minimum of 24" in front of the firebox opening and a minimum of 8" to either side of the firebox opening.

2.Floor protector must be 3/8" minimum thickness non-combustible material or equivalent.

3.If your fireplace has wood trim above it, the wood trim musts be at least 20" above the top of the unit and may be a maximum of 1/2" thick.

4.If your fireplace has a wood mantel, the mantel or mantel supports must be located at a height of 30" above the top

Page 10
Image 10
New Buck Corporation 91 manual Minimum Clearances

FAQ

What materials should the hearth be constructed of?

The hearth must be of masonry construction and extend a minimum of 24" in front of the firebox opening and a minimum of 8" to either side of the firebox opening.

Can I install the Model 91 Bay Fireplace Insert into a pre-fabricated fireplace?

No, this model is not intended for installation into a Zero Clearance or pre-fabricated fireplace as per NFPA-211 Code.

How high should the wood trim above the fireplace be?

The wood trim must be at least 20" above the top of the unit and may be a maximum of 1/2" thick.