Intellipad Wiring
When you are placing both a Intellipad and a sensor (or
two keypads) in one room you may “daisy-chain” using a
single cable. A cable is run between the keypad and the
sensor and a single cable is run from the sensor back to the
MSU140. To prevent data feedback an IN4003 Blocking
Diode is inserted on the data (IR) line between the
Intellipad and the sensor. The cathode, or blocking side of
the diode, faces the Intellipad. See Figure 5. Note that the
status wire is connected to Intellipad’s status (+) connector.
7
I
NFRARED
M
AIN
S
YSTEM
U
NIT
1234
POWER
+12V DC
3-30V
AC/DC
STATUS
IN
FLASHER OUTPUTS
MSU140
IR MAIN SYSTEM UNIT
INPUT 1
Figure 5:An IR sensor
cable is “daisy-chained”
from an Intellipad, to a
sensor and back to the
MSU140.
IN4003
Blocking
Diode
DS00329BCN-MSU140-1.qxp 8/17/05 11:26 AM Page 7