TROUBLESHOOTING GUIDE
TROUBLESHOOTING GUIDE
When there is a problem consult this guide first. If the problem persists, or you have additional questions, call your local Niles dealer or call Niles Technical Support at
SYMPTOM | POSSIBLE CAUSES AND TEST PROCEDURE |
No sound on one channel | BusMatrix DIP switch is not in the correct position. |
| Check your configuration worksheet for the correct |
| setting and verify. |
| Short circuit or loose wire at speaker or amplifier |
| terminals. Check that connections are secure and |
| that there are no loose strands of wire crossing from |
| the positive to the negative terminal at the back of |
| the amplifier and the speaker. |
| Short circuit or a break in the speaker wire. Dis- |
| connect the speaker wire at both ends, separate the |
| 2 conductors at both ends and test with a meter for |
| a short circuit. If there is no short, connect the two |
| conductors at one end and test with a meter for |
| continuity. |
| Speaker is not working. Connect the speaker to a |
| channel that plays another speaker. |
| Audio cable to dedicated input is bad. Connect the |
| |
| known to be good. |
| Bridging Switch is in the wrong position. Check |
| your configuration worksheet for the correct setting |
| and verify. |
| The thermal protection circuit has operated because |
| of overheating caused by overdriving or inadequate |
| ventilation. |
|
|
No sound on some or all | BusMatrix DIP switches are not in the correct posi- |
channels | tions. Check your configuration worksheet and |
| verify all settings. |
| Audio cable to the main bus inputs is bad. Connect |
| the |
| that is known to be good. |
| Some or all of the internal amplifier fuses are blown. |
| (Return the amplifier to your dealer for service). |
|
|
27