12.0 Diagnosis of faults and repair | EN |
|
|
Fault | Cause | Repair |
The motor fails to start | Oil supply not connected | Connect the oil hose |
| Oil supply closed | Open the valve |
| No oil pressure | Start the hydraulic pump |
| The pump is frozen | Let the pump thaw |
|
|
|
Working pressure too high | Nozzle partly blocked | Clean the nozzle |
|
|
|
Working pressure too low | Valve for regulation of water | Open fully the valve for regulation |
| capacity is not adjusted to max. | of water. Turn in the direction |
| pressure | indicated by the arrow |
| Regulating valve open | Close the regulating valve |
|
|
|
Irregular working pressure | Air in the pump | Repeat the venting procedure |
During | Suction height too high or water | Read the paragraph conc. self- |
| too hot | priming p. 6 |
| Filter blocked | Clean the fi lter. See p. 11 |
During direct water | Insuffi cient water supply from | Change to a water supply with |
connection | the water works | greater output. If this is not |
|
| possible; turn the valve for regulation of |
|
| the water capacity in the opposite |
|
| direction of that indicated by the |
|
| arrow, until the machine works smoothly. |
|
|
|
No working pressure | Nozzle blocked | Clean the nozzle |
| No water | Check the water connection |
| High pressure hose/lance frozen | Allow the high pressure hose/lance |
|
| to thaw |
| Allow the machine to thaw | |
|
|
|
Should faults occur other than those mentioned above, please contact the nearest Nilfi
16