5.0 Operation

EN

 

 

5.1 Starting-up procedure

1.Check the oil level in the oil glass. The level should be maintained between the MIN. and MAX. marks. This applies also for the oil level in the oil-mist lubricator (pos. 5).

2.Run water through the inlet hose before connec- ting, in order to remove possible impurities in the hose. Connect the hose.

3.Connect the quick coupling (a) of the high pres- sure hose to the outlet socket.

4.Check the input end of the spray lance (b) for possible impurities. Pull forward the grey trigger

(c) of the spray handle. Connect the input end of the spray lance to the quick coupling. Release the grey trigger.

5.Press the trigger of the spray handle (d) and allow the water to run, until the system has been completely vented. For self-priming it is recommended to open the regulating valve (e) during the venting.

6.Release the trigger of the spray handle (d) and turn on the air supply. The pump will now be in idle motion.

7.For cleaning at high pressure press home the trigger of the spray handle after having closed the regulating valve.

8.For cleaning at low pressure open the regula- ting valve. When cleaning at low pressure the chemical injector will allow supply of detergents according to the scale of the injector situated at the water outlet.

e

b c

d

a

Operation EN

5.2 Stopping

1.Turn off the air supply.

2.Turn off the water supply.

3.Press home the trigger of the spray handle to relieve the pressure of the cleaner.

4.Do not disconnect the high pressure hose, until the cleaner has cooled down and stopped.

6.0 Frost proofing EN

Operation and storage in frosty weather (below 0°C).

Never leave the cleaner unless it has been emptied of water, not even for a short period. Empty the cleaner in the following way:

1.Disconnect and empty both the water supply and the high pressure hoses.

2.Start the pump and allow it to run until it is empty.

If the cleaner is not stored in a frost-proof place between operations, it should be protected from frost in the following way:

1.Disconnect the lance.

2.Start the machine and allow it to run without water.

3.Place the suction hose into a container of anti- freeze.

4.Draw in the antifreeze from the container by activating the spray handle. Having placed the spray handle above the antifreeze funnel, open and close it a few times, so that the antifreeze can circulate.

5.Remove the inlet hose from the container. Acti- vate the spray handle and allow the rest of the antifreeze to run back into the container.

NB! The antifreeze will be diluted with water and will after some time lose its effect.

IMPORTANT:

To avoid damage always ensure that the cleaner, the hoses and the spray lance are unfrozen before restarting. Place the cleaner and the accessories in a warm place for some time before starting up.