ATTIX
ATTIX 12 GALLON / ATTIX 12 GALLON RDF ATTIX EC 12 GALLON AS/E
Fault
Cause
Remedy
‡ Reduced suction power | > | Suction power selected with | · | Set suction power in ac- | |
|
| suction power control1) is to | |||
|
| low. | · | cordance with section 4.2.3. | |
| > | Clogged suction hose/noz- | "Suction power control". | ||
|
| zle. | Clean suction hose/nozzle. | ||
| > Seal/tank rim between the | · | Clean/replace seal. | ||
|
| upper section of the cleaner | |||
|
| and the dirt tank is dirty/de- |
|
| |
|
| fective. | · See section 7.2.2 "Replac- | ||
| > Filter bag is full. | ||||
|
|
| |||
| > Filter element is clogged. | · | ing the filter bag". | ||
|
|
| See section 4.3 "Cleaning | ||
|
|
|
| the filter element" and 7.2.3 | |
|
|
|
| "Replacing the filter ele- | |
‡ No suction power during wet | > | Tank is full (floater closes | · | ment". | |
Switch off the cleaner. | |||||
cleaning |
| the suction opening). |
Empty the tank.
‡ Voltage fluctuations | > Impedance of power supply |
| is too high. |
·
·
Use a suitable extension cord (see section 9.4 "Tech- nical data").
Connect the cleaner to another socket closer to the fuse box. Voltage fluc- tuations over 7 % should not occur if the impedance at the transfer point is
≤0.15 Ω.
9 Further information
9.1Recycling the vacuum Make the old cleaner unusable
cleanerimmediately.
1. Unplug the cleaner and cut the power cord.
The cleaner contains valuable materials that should be re- cycled. Therefore, make use of your local waste disposal site.
Contact your local authorities or your nearest dealer for further information.
9.2 Guarantee | Our general conditions of busi- |
| ness are applicable with regard |
| to the guarantee. |
| Subject to change as a result of |
| technical advances. |
1) Option depending on model | 23 |