ATTIX
ATTIX 12 GALLON / ATTIX 12 GALLON RDF ATTIX EC 12 GALLON AS/E
5
8 Troubleshooting
4
6
Check it for damage and replace if necessary.
5.Check antistatic clamp (5) for damage and have it replaced by Alto Service if necessary.
6.Check the floater (6) for proper operation: When you turn the filter holder, the floater should move back and forth easily.
7.Fit a new filter element.
8.Fit the filter holder and turn it clockwise to secure it.
9.Dispose of the used filter element in accordance with legal regulations.
CAUTION!
Never use the vacuum clean- er without a filter.
Fault
‡Motor does not start
Cause
>Fuse in mains plug has blown.
>Overload protection switch has tripped.
>
Remedy
•Reset the fuse.
•Switch off the vacuum clea- ner and allow it to cool for approx. 5 minutes. If it can not be started again, contact the Alto service department.
•Have carbon brushes changed by Alto Service.
‡ Motor does not run in auto-
matic mode1)
> Power tool is defective or
not connected properly.
>The power rating of the elec- trical tool is too low.
•Check that the power tool
works or that the plug is inserted correctly.
•Note that minimum power rating is P>40W
22 | 1) Option depending on model |