8 Troubleshooting
ATTIX 8 GALLON ATTIX 8 GALLON AS/E
english
Fault
‡ Motor does not start
Cause
>Fuse in mains plug has blown.
>Overload protection switch has tripped.
Remedy
•Reset the fuse.
•Switch off the vacuum cleaner and allow it to cool for approx. 5 minutes. If it can not be started again, contact the Alto service department.
‡Motor does not run in automatic mode1)
>Power tool is defective or not connected properly.
•Check that the power tool works or that the plug is inserted correctly.
‡ Acoustic warning 1) is heard | > | Suction power selected with |
(reduced suction power) |
| suction power control1) is too |
|
| low. |
| > Hose diameter does not | |
|
| correspond to suction hose |
|
| diameter setting. |
| > | Clogged suction hose/ |
|
| nozzle. |
> Seal/tank rim between the upper section of the cleaner and the dirt tank is dirty/ defective.
•Set suction power in accord- ance with section 4.2.3. "Suction power control".
•Set suction hose diameter setting1) to correspond to hose diameter.
•Clean suction hose/nozzle.
•Clean/replace seal.
>Filter bag is full.
>Filter element is clogged.
•See section 7.2.2 "Replacing the filter bag".
•See section 4.4 "Cleaning the filter element" and 7.2.3 "Replacing the filter ele- ment".
‡No suction power during wet cleaning
>Tank is full (floater closes the suction opening).
•Switch off the cleaner. Empty the tank.
‡ Voltage fluctuations | > Impedance of power supply |
| is too high. |
•Connect the cleaner to another socket closer to the fuse box. Voltage fluctua- tions over 7 % should not occur if the impedance at
the transfer point is ≤ 0.15 Ω .
1)Option depending on model
13